Device Status Settings - FineControl LS-20 Operation Manual

The universal box home management gateway
Table of Contents

Advertisement

8.4 Device Status Settings:

*Device Bypass (default= No): (For all devices)
Bypass = Yes: The system will ignore the trigger signal from this sensor.
*Delay Activation(default= Yes): (For Controller & Burglar sensor)
Delay Activation =Yes: (Refer to Exit Delay/Entry Delay.)
For the Remote Controller, the Exit Delay time will be imposed on the Away command from
For the Burglar sensor, the Entry Delay time will be imposed on the Burglar alarm signal
Delay Activation=No: The trigger signal or command from this device will be processed
this controller.
from this sensor.
immediately, regardless of the Exit/Entry Delay Time.
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents