Huawei AR530&AR550 Series Industrial Switch Routers
Configuration Guide - Device Management
The alarm severity is displayed.
Step 4 Run:
alarm-name alarm-name severity severity
The alarm severity is changed.
The system has defined default alarm severity for each alarm.
----End
5.4.1.2 Configuring the Alarm Reporting Delay Function
Context
When an alarm is reported repeatedly, users cannot locate faults in an efficient manner. After
the alarm reporting delay function is enabled and the delay is configured, a large number of
invalid alarms are prevented from being reported.
After the alarm reporting delay function is enabled,
l
l
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
alarm
The alarm view is displayed.
Step 3 Run:
delay-suppression enable
The alarm reporting delay function is enabled.
By default, the alarm reporting delay function is enabled.
Step 4 (Optional) Run:
display alarm information [ name alarm-name ]
The delay in reporting alarms is displayed.
Step 5 (Optional) Run:
suppression alarm-name alarm-name cause-period cause-seconds
The delay in reporting alarms is configured.
The system defines a default delay in reporting alarms.
----End
Issue 01 (2014-11-30)
If no clear alarm is generated during the period, the alarm is reported to the NMS when the
period expires.
If a clear alarm is generated during this period, the alarm and its clear alarm are both deleted
from the alarm queue and will not be reported to the NMS.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Fault Management Configuration
105