Pre-configuration Tasks
Before configuring alarm management, complete the following task:
Powering on the device and ensuring a successful self-check

5.4.1.1 Setting the Alarm Severity

Context
The system defines default alarm severity for each alarm. Users can change the alarm severity.
When receiving alarms reported by a device, the NMS can configure filtering rules to display
only alarms of a specified severity.
As defined in X.733, alarms are classified into six severities, as described in
value indicates a higher severity.
Table 5-3 Descriptions of alarm severities
Value
1
2
3
4
5
6
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
alarm
The alarm view is displayed.
Step 3 (Optional) Run:
display alarm information [ name alarm-name ]
Issue 01 (2014-11-30)
Severity
Description
Critical
Indicates that a fault affecting services has occurred and it
must be rectified immediately.
Major
Indicates that services are being affected and related
measures need to be taken urgently.
Minor
Indicates that a fault occurs but does not affect services. To
avoid a minor alarm from getting severer, related measures
must be immediately taken.
Warning
Indicates that a potential or impending service-affecting fault
is detected before any significant effects have been felt. Take
corrective actions to diagnose and rectify the fault.
Indeterminate
Indicates that the severity of an alarm cannot be determined.
Cleared
Indicates that one or more previous alarms have been cleared.
Huawei Proprietary and Confidential