Fetco CBS-2141 Users Manual And Operator Instructions page 9

Extractor touch screen models
Hide thumbs Also See for CBS-2141:
Table of Contents

Advertisement

OUTPUTS
Programming Items
Show Summary
• Output Summary
Left Valve
• Left Valve Test
Test OR Calibrate
• L. Valve Calib
'' ''
'' ''
L. Bypass Valve
Left Bypass
Test OR Calibrate
Valve Test
If bypass option availble
• L. Bypass Valve
'' ''
'' ''
Calib
Left Valve display is only for CBS-2102XTS dual side brewer. CBS-2101XTS Single series displays RIGHT SIDE only
Right Valve
• Right Valve Test
Test OR Calibrate
• R. Valve Calib
'' ''
'' ''
R. Bypass Valve
Right Bypass
Test OR Calibrate
Valve Test
If bypass option availble
• R. Bypass
'' ''
'' ''
Valve Calib
Fill Valve
• Fill Valve Test
• Left brew basket
Left Basket Lk.
lock test
Not on CBS 2130XTS
• Right brew
Right Basket Lk.
basket lock test
Not on CBS 2130XTS
Heater
• Heater Test
Screen
• Screen Contrast
Brightness OR Contrast
• S. Brightness
Default-factory set Flow Rates; Brew Valve and Bypass
See "OUTPUTS" right and left brew valve and bypass valve settings and calibration
CBS-2152 & CBS-2162 ml/min
Left Brew FR
Left Bypass FR
Right Brew FR
Right Bypass FR
CBS-2132& CBS-2142 ml/min
Left Brew FR
Left Bypass FR*
2150
Right Brew FR
Right Bypass FR
--------------------------------------------------------------------------------------------------------------------
Go to fetco.com for the latest versions of all information
Factory set Default
(Press to test)
Calibrate
*Flow Rate
(Press to test)
Calibrate
*Flow Rate
(Press to test)
Calibrate
*Flow Rate
(Press to test)
Calibrate
*Flow Rate
(Press to test)
(Press to test)
(Press to test)
(Press to test)
Contrast
Brightness
3200
2400
3200
2400
1540
2150
*
1540
2150
Programming Range (display)
Left Brew FR
Left Bypass FR
Right Brew FR
Right Bypass FR
Screen Contrast
Screen Brightness
TEST
Press To Test
1540 to 3200 ml p m
|_________[]________|
1400-2800
TEST
Press To Test
2150 to 2400 ml p m
|_________[]________|
1900-2100
TEST
Press To Test
1540 to 3200 ml p m
|_________[]________|
1400-2800
TEST
Press To Test
2150 to 2400 ml p m
|_________[]________|
1900-2100
TEST
Press To Test
TEST
Press To Test
TEST
Press To Test
TEST
Press To Test
|____________[]____|
1
|____________[]____|
1
CBS-2151& CBS-2161ml/min
Right Brew FR
3200
Right Bypass FR
2400
CBS-2131&CBS-2141 ml/min
*
Right Brew FR
1540
*
Right Bypass FR
Page 9
Part A-User Guide & Operator instructions
3200
2400
3200
2400
FR=Flow Rate ml/min
8
8
Touch To Return
Runs valve to verify
flow. Have container
TEST
under brew-basket!
Factory or service use
for flow rate adjustment
1950-3800
Runs valve to verify
TEST
flow. Have container
under brew-basket!
Factory or service use
for flow rate adjustment
2800
Runs Valve to verify flow.
Have container under
TEST
Factory or service use
1950-3800
Runs valve to verify
flow. Have container
TEST
under brew-basket!
Factory or service use
for flow rate adjustment
2800
Operates fill valve.
TEST
Have container under
both brew-baskets!
Energizes brew basket
lock. For factory or
TEST
Energizes brew basket
lock. For factory or
TEST
Energizes Heater(s)
TEST
Service use only.
8
10
8
10
P130 Part A Rev. 002 March 2016
Notes
brew-basket!
for flow rate
service use
service use

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbs-2142xtsCbs-2100 xts

Table of Contents