7. Parameter Tables

7.1. Basic Parameters

Parameter
PIN entering mode
PIN – value
CLIR – incognito
Volume - direction to GSM
Volume - direction from GSM
Roaming enable/disable
Incoming calls rejection
GSM signal level indication
Delete SMS when SIM is full
Silence after dialling to GSM
End of dialling signal length
Dialling end time-out
Switchboard operator number
International prefix
Country code
Long distance code
Operator prefix
Tone after end of call
1st tone
Busy tone
1st pause
1st tone
1st pause
2nd tone
Dialling tone
2nd pause
3rd tone
3rd pause
1st tone
1st pause
Dialling tone
2nd tone
during
2nd pause
roaming
3rd tone
3rd pause
DTMF receiver
Min. burst
timing
Min. pause
DTMF transmitter
Tone
timing
Pause
Receiving DTMF during a call
Par.
Min.
Max.
No.
101
0
1
102
4 dig.
8 dig.
103
0
2
104
1
5
105
1
5
106
0
1
107
0
1
108
0
1
109
0
1
111
0
25500
112
0
2550
113
2000 15000 6000
114
Max. 8 digits
115
1 dig. 4 dig.
116
1 dig. 4 dig.
117
0 dig. 2 dig.
118
1 dig. 4 dig.
121
0
2
122
0
2550
123
0
2550
131
0
2550
132
0
2550
133
0
2550
134
0
2550
135
0
2550
136
0
2550
141
10
2550
142
10
2550
143
0
2550
144
0
2550
145
0
2550
146
0
2550
151
30
200
152
30
200
153
30
1000
154
30
1000
155
0
1
44
Your
Def.
Remarks
choice
1
0 = manually, 1 = automatically
-
Write-only parameter!
0 = by operator setting
0
1 = no CLIR, 2 = send CLIR
3
1 = minimum, 5 = maximum
3
1 = minimum, 5 = maximum
0
0 = disabled, 1 = enabled
0 = reject all incoming calls,
1
1 = normal operation
0
0 = disabled, 1 = enabled
1
0 = disabled, 1 = enabled
e.g.
Time [ms], step is 100.
0
Recommended value = 10000
10000
200
Beep length [ms], step 10
In milliseconds! Step = 100 ms
Usually 00.
00
Equal to "+" on GSM networks.
Sooner parameter 6002.
*)
Enter without "00" prefix, "+" will
be added automatically.
It may be empty - in some
-
countries it is not used.
-
Reserved for future use.
0 = silence, 1 = continuous,
2
2 = busy tone
320
Step = 10 [ms]
320
320
320
640
Step = 10 [ms]
640
0
0
320
320
320
Step = 10 [ms]
320
640
640
40
Step = 10 [ms]
40
100
Step = 10 [ms]
100
0 = disabled, 1 = enabled
1