Power-Up Error Blackout; Reset - Brainstorm SR-112 Owner's Manual

Time code distripalyzer
Hide thumbs Also See for SR-112:
Table of Contents

Advertisement

SR-112 User Manual (Rev 4.01)
Beeper:
The beeper sounds when a fatal error is detected. It can be deactivated in menu 06.
Warning LED:
after the sR-112 has detected a "fatal" error, the INPUT ERROR warning LED starts
flashing. This way, if you leave the room, you will know if an error occurred while you
were away.
To stop the LED from flashing manually, press any key.
The LED also stops flashing when the sR-112 is goes through an automatic reset.
LCD Display:
Press the [
scroll through the different errors, press the [
For each error detected, an error description appears on the top line and the faulty
address appears on the bottom line.
The left/right arrows are only present when there are more errors in that direction.
Right = increasing time codes; Left = decreasing.
The display is normally showing the most recent error, but arrowing to the left will
hold it at the error being viewed. It will return to displaying the most recent error if
the operator either (a) arrows all the way to the right, or (b) switches to a different
display and back (e.g. to the TC In status display, or to a Menu).
10.5 POWER UP ERROR BLaCkOUT
all error reporting is inhibited for a 20 second blackout period following power up.
Errors are ignored during that time.

10.6 REsET

Reset is achieved 2 different ways: automatically or manually.
Auto Reset: The sR-112 is reset automatically whenever the time code input reapears
after an interruption of 5 seconds or more.
Manual Reset: a manual Reset is done by pressing and holding the [
for 3 seconds or more. The 8 digit display will confirm this by indicating "- REsET -".
The following occurs after a reset:
INVaLID: Invalid Code
VID-LOsT: Video Loss - any interruption in the video signal.
TYPE CHG: Code Type or Format Change
DF CHG: Change in the Drop Frame status
CF CHG: Change in the Color Frame status
DF ERR: Drp Frame error - received a "00" or "01" frame where there should
have been a "02"
REsET: Manual Reset
] or [
] key until the ERROR page appears on the LCD display. To
up
down
• all LED's stop flashing
• a new sTaRT TIME is established and a new time code report started
• The error register is cleared
• The Drift detector is reset
] or [
] keys.
left
right
Page 15
] button
set up