Time Code Report
also included is the Device Name which can be edited. To change it, click on
the name area and a text box will open up. Type in a new name (up to 32 char-
acters) an hit Enter. Or hit Esc to get out without any change.
In the upper right corner is the UPDaTE FIRMWaRE button. Clicking this takes
you to a separate specialized page. see chapter 13.
The main section of the HTML page is a functional replica of the front panel.
The front panel switches and web page buttons operate in parallel, although web
page clicks are inhibited while any front panel key is being pressed. Status pages
can be selected by using the [
clicking on the [
set up
a REsET button has been added to the right of the sET UP button. Clicking on
REsET is the equivalent of holding the [
a popup window asks for confirmation before proceeding.
The displays and LED's are refreshed every second, plus immediately after any
button on the page is clicked. The frames digits on the 7-segment display will
blank while timecode is in motion but the seconds digits will be updated more or
less in real time since the page is refreshed every second.
A Time Code report is automatically generated in
REsHaPE and REPaIR modes as soon as the sR-112
receives valid time code. The report ends when time
code is interrupted for 5 seconds.
Reporting is disabled in GENERaTE mode.
The report header includes the start time, the Time Code
format and rate, the video format and the TC/Vid phase
(if video is present), the User Bits and the sR-112 operating
mode.
The current date is inserted at top of report. It is also
inserted into the report at reader 24-hour crossing.
Erros are listed as soon as they are detected with the
corresponding time code address. For a complete list of
error messages, see appendix C.
Below the report box are two buttons:
- PRINT REPORT: launches a popup containing the complete report text, together
with a standard Print command window. Note that text within the report window
can also be selected, then copied and pasted it into any text file.
- CLEaR REPORT: clears all text in the Time Code Report box. a pop up window
asks for confirmation before proceeding.