Programming Errors - Brainstorm SR-112 Owner's Manual

Time code distripalyzer
Hide thumbs Also See for SR-112:
Table of Contents

Advertisement

SR-112 User Manual (Rev 4.01)
The major software rev number will change whenever the FPGa or LOaDER changes.
This means that:
13.3 PROGRaMMING sEQUENCE
There are 3 steps in the normal programming sequence:
During this sequence, the 7-segment display shows all dashes (with regular soft-
ware also showing the time code decimal points -- not so with the Loader), and the
LCD sequences through the following displays:
Note: During the 3rd step (programming), Ethernet is internally disconnected.
Reboot

13.4 PROGRaMMING ERRORs

If an error occurs during the programming sequence, possibly due to a network error,
a power failure or a pulled cable, one of 3 error messages appears in the LCD display.
'Upload Error' is not very serious since the error was detected before the start of
programming. simply press any key and start again.
'Flash Error' is most likely similar to the previous error. Press any key and start again.
However, if the same message reappears right after, it means the corruption occurred
after programming had begun and the Loader procedure should be used.
- updates between any 3.xx version can be 'software' only,
- updates from, for example, 3.xx to 4.xx must be a "complete" update.
- UPLOAD
- VERIFY
- PROGRAM
• at the conclusion of a Flash programming sequence following the upload of
a "complete" image file, the display shows that a manual reboot is required.
• With a 'software' image file, the sR-112 automatically reboots.
Page 19

Advertisement

Table of Contents
loading

Related Products for Brainstorm SR-112

Table of Contents