OPERATING THE SPREADER – CAB CONTROL
CAB CONTROL CODES
Code
Definition
Cb
Calibrate the Empty Hopper setting.
Cc
Clear calibration data for Empty Hopper
setting; clear EH code.
LS
Set LED brightness level.
SL
Confirms that LED brightness level has
been reset.
* For full instructions, see the "Setup Procedures" section.
Code
Definition
dU
Spreader is in dump mode:
• Material chute is open.
• Back Dump buttons are enabled.
EH
Empty hopper (beep will sound).
Lb
Low battery. Hopper module is sensing
< 10V. (Lb becomes an error code
when module senses < 6V.)
Lit. No. 99761/99762, Rev. 02
Setup Codes
Procedure
With control in ON mode, press and hold the left control knob until the
Cb code displays. Calibration cycle is automatic.*
Press the right control knob to clear all calibration data during the
calibration cycle.
With control in Ready mode, press and hold left control knob to get
LS code. Release pressure and turn left control knob to desired
brightness setting. Wait for confirming SL code to display.*
Information Codes
Response
To operate the dump function, see instructions in the "Operating the
Spreader" section of this manual.
If dU code displays when the material chute is closed and latched,
contact authorized dealer.
Check hopper for material.
Recalibrate Empty Hopper setting as described above for Cb code.
Refer to the Lb row under "Error Codes" (next page).