Gpf Receive; Ethernet Performance Monitoring Screen; In (To Rf Transmit) - Alcatel-Lucent MDR-8000 User Manual

Microwave digital radios
Hide thumbs Also See for MDR-8000:
Table of Contents

Advertisement

Radio
RF RECEIVE
Errors
Error seconds
Severe Error Seconds
Severe Error Frame Seconds
BER
Radio Outage Sec
Radio A and B Outage Sec
Figure 6-8 Ethernet Radio, Radio Performance Screen

GPF Receive

6.6.2
Errors
6.6.2.1
Indicates total number of coding violations, slips, or frame losses in the Ethernet data.
Error Seconds
6.6.2.2
Any second during which a code violation was detected. Count is initiated during any
second that qualifies as Unavailable Second.
6.6.2.3
Severe Error Seconds
Any second during which the code violation count exceeds the number of errors that
could occur in one second at 1 x 10
that qualifies as Unavailable Second.
Severe Error Frame Seconds
6.6.2.4
Any second during which there is no start of frame for at least four consecutive frames.
6.7

ETHERNET PERFORMANCE MONITORING SCREEN

See Figure 6 - 9. Reset performance parameters to zero using the Error reset button on
the toolbar. TIME SINCE LAST RESET displays the time in days, hours, minutes, and
seconds since the last error reset.

IN (To RF Transmit)

6.7.1
Average Bytes/Sec
6.7.1.1
Indicates average number of frame bytes per second in the Ethernet RCV/radio XMT
data.
Communicating*
Ethernet
A
B
GFP RECEIVE
Errors
0
0
Error Seconds
2
0
Severe Error Seconds
2
0
Severe Error Frame Seconds
2
0
BER
1.0 E-14
1.1 E-14
2
2
-6
error rate. Count is inhibited during any second
A
B
4
0
12
0
12
0
4
0
2.9 E-12
1.5 E-12
MDR-1202
08/15/05
6 - 9

Advertisement

Table of Contents
loading

Table of Contents