Ds1/E1 Radio Performance Screen - Alcatel-Lucent MDR-8000 User Manual

Microwave digital radios
Hide thumbs Also See for MDR-8000:
Table of Contents

Advertisement

DS1/E1 RADIO PERFORMANCE SCREEN

6.3
See Figure 6 - 3. The Analog Monitor screen is used to display real-time analog voltages
and radio performance monitors for the ELMC address. Analog voltages are updated
automatically every second. Reset performance parameters to zero using the Error
Reset button (or hotkey F3) on the toolbar. TIME SINCE LAST RESET displays the
time in days, hours, minutes, and seconds since the last error reset.
6.3.1
Repeater CRC Err Sec
Repeater CRC Errored Seconds, indicates number of seconds that contain coding viola-
tions, slips, or frame losses in the data over the repeater cable.
Radio Severe Err Sec
6.3.2
Radio Severe Errored Seconds, indicates number of seconds that contain a predeter-
mined number (N) of coding violations in the data over the RF path.
Radio Outage Sec
6.3.3
Radio Outage Seconds, indicates on-line RCVR errored seconds (number of seconds
that contain coding violations, slips, or frame losses in the data over the RF path).
Radio A and B Outage Sec
6.3.4
Radio A and B Outage Seconds, indicates on-line and off-line RCVR errored in the
same second.
Radio CRC Err Sec
6.3.5
Radio CRC Errored Seconds, indicates number of seconds that contain coding viola-
tions, slips, or frame losses in the data over the RF path.
6.3.6
Radio CRC Errors
Indicates number of errors in the data over the RF path.
Radio Internal BER
6.3.7
Indicates current BER of the data over the RF path.
Radio Average BER
6.3.8
Indicates average BER of the data over the RF path since last reset.
6 - 3

Advertisement

Table of Contents
loading

Table of Contents