The information contained in this section is a summary of the sec-
tion with the same title, but not the same section number, on the
enclosed CD. "Refer to CD" is used throughout this section to refer
the reader to the detail information on the CD. Go to this section on
the CD for interactive links to the detail information referred to in
this section.
USER GUIDE
6

INTRODUCTION

6.1
This section contains descriptions of screens not used or described in other sections.
Where there are operational differences, DS1/E1, DS3, and OC3/STM-1 and/or ETH
screens are shown separately.
ANALOG SCREEN
6.2
See Figure 6 - 1 and Figure 6 - 2. The Analog screen is used to display real-time analog
voltages and radio performance monitors for the ELMC address. Analog voltages are
updated automatically every second. Reset performance parameters to zero using the
Error Reset button (or hotkey F3) on the toolbar. TIME SINCE LAST RESET displays
the time in days, hours, minutes, and seconds since the last error reset.
PA (DC MON)
6.2.1
Indicates PA RF output level (Vdc).
TX (PWR MON)
6.2.2
Indicates XMTR module RF output level (Vdc).
ATPC Voltage
6.2.3
Indicates ATPC CONTROL signal output from controller to XMTR module(s) (Vdc).
6.2.4
RX (RSL 1) dBm
Indicates AGC MON output level from RCVR module (dBm).
RX (EYE MON)
6.2.5
Relative measure of noise level of receive signal (Vdc).
RX (AFC MON)
6.2.6
Indicates AFC MON output from single RCVR module (-3 Vdc = nominal frequency).
(The AFC MON signal is developed from the correction voltage applied to the crystal
oscillator on the single RCVR module.) Not provided by design and replaced with Path
Distortion on dual RCVR module.
Battery Voltage
6.2.7
Indicates battery power input (Vdc).