Radio Error Seconds; Radio Severe Error; Radio Ber; Ethernet Radio Performance Monitoring Screen - Alcatel-Lucent MDR-8000 User Manual

Microwave digital radios
Hide thumbs Also See for MDR-8000:
Table of Contents

Advertisement

Radio Error Seconds

6.5.8
Any second during which a code violation was detected. Count is initiated during any
second that qualifies as Unavailable Second.
6.5.9

Radio Severe Error

Any second during which the code violation count exceeds the number of errors that
could occur in one second at 1 X 10
that qualifies as Unavailable Second.

Radio BER

6.5.10
Calculated from code violation count and data rate.

ETHERNET RADIO PERFORMANCE MONITORING SCREEN

6.6
See Figure 6 - 8. Reset performance parameters to zero using the Error reset button on
the toolbar. TIME SINCE LAST RESET displays the time in days, hours, minutes and
seconds, since the last error reset.

RF Receive

6.6.1
Errors
6.6.1.1
Indicates total number of coding violations, slips, or frame losses in the Ethernet data.
Error Seconds
6.6.1.2
Any second during which a code violation was detected. Count is initiated during any
second that qualifies as Unavailable Second.
Severe Error Seconds
6.6.1.3
Any second during which the code violation count exceeds the number of errors that
could occur in one second at 1x 10
that qualifies as Unavailable Second.
Severe Error Frame Seconds
6.6.1.4
Any second during which there is no start of frame for at least four consecutive frames.
BER
6.6.1.5
Calculated from code violation count and data rate.
6.6.1.6
Radio Outage Sec
Radio Outage Seconds, indicates on-line RCVR errored seconds (number of seconds
that contain coding violations, slips, or frame losses in the data over the RF path).
Radio A and B Outage Sec
6.6.1.7
Radio A and B Outage Seconds, indicates on-line and off-line RCVR errored in the
same second.
6 - 8
-6
error rate. Count is inhibited during any second
-6
error rate. Count is inhibited during any second

Advertisement