SERVICE DATA

⊙ ⊙ EI SENSORS
ITEM
IAP sensor input voltage
IAP sensor output voltage
TP sensor input voltage
TP sensor output voltage
IAT sensor resistance
IAT sensor resistance (each temperature)
RO switch resistance
GP switch resistance
Oxygen sensor heater voltage
SAV solenoid voltage
ET sensor resistance
ET sensor resistance ~To ECU₩
(each temperature)
SPECIFICATION
4.5 ~ 5.5 V
Approx. 3.7 ~ 3.9 V when ignition switch "ON"
4.5 ~ 5.5 V
Closed
Opened
0.081 ~ 48.352
~When Intake air temperature is
-40℃ ~ 130℃ (-40℉ ~ 266℉)₩
Refer to page 48 (4-1-33)
Ω (Infinity) ~at normal condition₩
0 Ω ~at leaned more than 60。 ₩
100 Ω~ 2.0
Battery voltage
Battery voltage
0.102 ~ 81.000
~When Engine temperature is
-20℃ ~ 180℃ (-4℉ ~ 356℉)₩
-20 ℃ (-4 ℉ )
0 ℃ (32 ℉ )
20 ℃ (68 ℉ )
40 ℃ (104 ℉ )
60 ℃ (140 ℉ )
80 ℃ (176 ℉ )
120 ℃ (248 ℉ )
140 ℃ (284 ℉ )
160 ℃ (320 ℉ )
180 ℃ (356 ℉ )
91
SERVICING INFORMATION 7-19-1
Approx. 0.3 V
Approx. 4.5 V
Approx. 75.5
Approx. 28.7
Approx. 12.2
Approx. 5.6
Approx. 2.8
Approx. 1.5
Approx. 0.5
Approx. 0.3
Approx. 0.2
Approx. 0.13