STAND-BY SCREEN

This screen is displayed at start-up. It indicates that the appliance is ready to respond when a demand is
FR
received.
NL
ES
IT

LOCKOUT SCREEN

DE
If a problem occurs, the Lockout screen replaces the Home screen. The backlight also remains on as long
as the problem is not solved. Pressing any arrow button will return to the Home screen.
Using the code located in the right bottom corner of the screen, troubleshoot the problem, either with
the table located in paragraph "In case of Problem..." on page 7, or with the Lockout code table in the
Installer's Handbook (for the installer only).
PL
Low Water
RU
Water pressure has fallen below
0.7 bar. Increase pressure
to normal range.
If problem persists,
call for service
en
6
HeatMaster
84°C
61°C
Target = --
Stand-by
Lockout message. Refer to "In case of Problem..."
on page 7 for more information.
Body text. The first sentence describes the lockout,
the second sentence gives a possible cure, and the
third tells how to reset the lockout.
E37
Lockout reference code. Refer to "In case of Prob-
lem..." on page 7 for more information.

STATUS MESSAGES

Stand-by
Indicates that the appliance is ready to respond when a demand is received.
CH Demand
A central heating call has been received.
DHW Demand
A domestic hot water call has been received.
CH / DHW Demand
Central heating and domestic hot water calls are being received simultaneous-
ly. Both calls are being satisfied simultaneously because domestic hot water
priority has been disabled.
DHW Priority
Central heating and domestic hot water calls are being received simultaneous-
ly. Domestic hot water call is being satisfied first because it has priority over
central heating calls.
Priority Timeout
Central heating and domestic hot water calls are being received simultaneous-
ly. The domestic hot water priority time limit has been exceeded. Priority will
now switch back and forth between central heating and domestic hot water
calls until one call is satisfied.
External Demand
An external modulation call has been received.
Manual Operation
The burner or circulators have manually been enabled in the Installer Menu.
CH Burner Delay
The burner will not fire until the call blocking time has elapsed.
DHW Burner Delay
The burner will not fire until the call blocking time has elapsed.
CH Setpoint Reached
The burner is not fired because the supply/system water temperature exceeds
the setpoint. The central heating circulator continues to operate and the burner
will fire again once the supply/system water temperature drops below the set-
point.
DHW Setpoint Reached
The burner is not fired because the supply/system water temperature exceeds
the setpoint. The domestic circulator continues to operate and the burner will
fire again once the supply/system water temperature drops below the setpoint.
CH Post Pump
The central heating circulator is running to remove heat from the HeatMaster at
the completion of a call.
DHW Post Pump
The domestic hot water circulator is running to remove heat from the HeatMas-
ter at the completion of a call.
Freeze Protection
The burner is fired because the freeze protection feature has been activated.
Freeze protection will end once the supply/system water temperature is raised
to16°C.
Boiler Protection
The burner firing rate is being reduced because of an excessive difference be-
tween the appliance supply and return temperatures. The firing rate will begin
increasing once the temperature difference is less than 25°C.
Lockout Description
The lockout which currently has the HeatMaster shut down is displayed