Download Print this page

Electrical Specifications - AEMC JM861 User Manual

Ac current probe

Advertisement

ELECTRICAL SPECIFICATIONS

Current Range:
1 to 30A AC continuous cycle; 90A peak to peak
1 to 300A AC continuous cycle; 900A peak to peak
1 to 2400A AC continuous cycle; 9000A peak to peak
1 to 2400A AC continuous cycle for the
full temperature range
(3000A if temperature is < 35°C or 95°F)
Output Signal:
10 mV AC/A AC (0.3V at 30A)
1 mV AC/A AC (0.3V at 300A)
0.1 mV AC/A AC (0.3V at 3000A)
1.97 x 5.31" (50 x 135 mm) or
2.52 x 3.94" (64 x 100 mm)
4.72"
(120 mm)
Ø=2.52" (64 mm)
Cable max.
Bus Bar max.
1.89"
(48 mm)
Accuracy and Phase Shift*:
30A RANGE
Primary current
Accuracy %
Phase shift
300A RANGE
Primary current
Accuracy %
Phase shift
12.40"
(315 mm)
P1
P2
1.5A
6A
2% ± 1 mV
20°
10°
15A
60A
2% ± 0.5 mV
1.5°
30A
300A

Advertisement