3000A RANGE
Primary current
150A
Accuracy %
Phase shift
(*Reference conditions: 23°C±3°K, 20 to 85%
RH, 48 to 65 Hz, external magnetic field < 40
A/m, no DC component, no external current
carrying conductor, test sample centered.)
Load impedance ≥ 1MΩ, 47 pF.
Accuracy: Per IEC 185
Ampere Second Product: 90 A.S
Frequency Range: 10 to 50 kHz; current
derating above 5 kHz for continuous use
Load Impedance: 1 MΩ, 47 pF
Working Voltage: 600V AC
Common Mode Voltage: 600V AC
Influence of Adjacent Conductor:
0.005A/A AC
Influence of Conductor in Jaw Opening:
1% ± 0.1A of reading
Influence of Frequency from 10Hz to 10kHz:
1 dB on all ranges
Influence of DC Voltage: 0.05% per A DC

MECHANICAL SPECIFICATIONS

Operating Temp.: 14° to 122°F (-10° to 50°C)
Storage Temp.: -40° to 176°F (-40° to 80°C)
Influence of Temperature: < 0.1% per 10°K
Jaw Opening: 3.54" (90mm)
Maximum Conductor Size:
Cable: 2.52"  max. (64mm)
Bus bar: 1.97 x 5.31" (50 x 135mm)
2.52 x 3.94" (64 x 100mm)
Envelope Protection: IP 20 (IEC 529)
Drop Test: 500 mm (IEC 68-2-32)
600A
3000A
2% ± 0.2 mV
1.5°
Mechanical Shock: 100 g (IEC 68-2-27)
Vibration:
10/55/10 Hz, 0.15 mm (IEC 68-2-6)
Polycarbonate Material:
Handles: 10% fiberglass charged
polycarbonate UL 94 V0
Jaws: ABS UL 94 V2
Dimensions:
4.72 x 12.40 x 1.89" (120 x 315 x 48 mm)
Weight: 2.65 lbs. (1200 g)
Colors: Dark gray handles with red jaws
Output:
Insulated 6.5 ft. (2 m) coaxial cable with insulated
BNC connector rated 600V rms

SAFETY SPECIFICATIONS

Electrical:
Double insulation or reinforced insulation
between primary or secondary and outer case of
handle upon IEC 1010-2-32
Common Mode Voltage:
600V CAT III, Pollution: 2

ORDERING INFORMATION

Current Probe JM861 ................... Cat #2110.90
Accessories:
Banana/BNC Connector XF-SS
(4 mm banana plug) ....................... Cat #2111.32