OPTIONS
Switching the Lever Pattern
The operating pattern of the left and right operating levers can be changed.
Before operating the machine, check the selector to see which operating pattern the
left and right operating levers are set for.
� When checking the machine's operation, first check the surrounding area, then
operate the machine slowly.
� Before changing the operating pattern, ground the working equipment, stop the
engine, then set the safety lock lever to the locked position.
A
ISO
G
JCB
Switching the Lever Pattern
(A) : ISO pattern
(G) : JCB pattern
WARNING
G
A
2
1
D5L003
169
1. Open the left side cover.
2. Loosen the wing bolt (1) from selector
valve.
3. Turn the lever (2) to switch the pattern.
4. Tighten the wing bolt (1) and fasten the
lever (2) in place.
5. Close the left side cover and check the
lever pattern.
C4L004