5.13 Bearing Housing Lubrication

See Graphic: wc_gr003179
5.13.1 Remove plastic fill plug (b) from top of bearing housing. Oil level
5.13.1 Remove plug (d) from bottom of bearing housing.
5.13.2 Replace drain plug and add 470 ml (16 oz.) of 15W40 oil through port
wc_tx000567gb.fm
Check oil level in housing daily before starting. Add oil as required.
Change oil every 300 hours.
To check oil level:
should be near center of drive shaft. Add oil as required.
To change oil:
(b) on top of bearing housing. DO NOT overfill housing.
Inspect drained oil. If oil is dirty or feels watered down, inspect pump
and bearing housing seals.