Page 3
Foreword Engine exhaust, some of its constituents, and certain vehicle components contain or emit chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. WARNING Foreword This manual provides information and procedures to safely operate and maintain this Wacker model.
Page 4
Nameplate / Typenschild / Placa de Identificación / Plaque signalétique A nameplate listing the Model Number, Item Number, Revision, and Serial Number is attached to each unit. Please record the information found on this plate so it will be available should the nameplate become lost or damaged. When ordering parts or requesting service information, you will always be asked to specify the model, item number, revision number, and serial number of the unit.
OPERATION Safety Notes This manual contains NOTES, CAUTIONS, and WARNINGS which must be followed to prevent the possibility of improper service, damage to the equipment, or personal injury. Notes: Notes contain additional information important to a procedure. CAUTION: Cautions provide information important to prevent errors which could damage machine or components.
OPERATION Operating Safety Familiarity and proper training are required for the safe operation of equipment! Equipment operated improperly or by untrained personnel can be dangerous! Read the operating instructions and familiarize yourself with the location and proper use of all instruments and controls. WARNING NEVER use pump to pump low flash point fluids ALWAYS check power supply before connecting...
OPERATION Installation Connection to Power Supply 1. Check voltage at installation site. It must match the This pump is equipped with a 3-wire cord rated for voltage requirements of the pump. Refer to “Technical outdoor use. Data” in this manual or the Dataplate attached to the pump.
OPERATION 1.10 Use of Extension Cords 1.12 Periodic Maintenance Extension cords should be used only when absolutely Before Use - Check cable and extension cords for wear necessary. When a long extension cord is used, a and damage. voltage loss occurs. The longer the cord the greater the voltage loss.
OPERATION 1.14 Cleaning Impeller If pump performance drops off, check for impeller wear and dirt accumulation in volute housing Remove three hex nuts from bottom of pump and remove strainer from pump. Remove nuts holding suction cover to pump and remove cover to expose impeller.
Page 13
EC - CONFORMITY CERTIFICATE EG-KONFORMITÄTS ERKLÄRUNG CE-CERTIFICADO DE CONFORMIDAD CERTIFICAT DE CONFORMITÉ DE LA CEE WACKER CORPORATION - MENOMONEE FALLS, WISCONSIN USA hereby certify that the construction equipment specified hereunder bescheinigt, daß das Baugerät certifica que la máquina de construcción atteste que le matériel 1.