Advertisement

www.wackergroup.com
OPERATOR'S MANUAL
0
1
5
4
6
3
1
E
N
0154631en
0102
Pump
STP400
STP750
001

Advertisement

Table of Contents
loading

Summary of Contents for WACKER Group STP750

  • Page 1 0154631en 0102 Pump STP400 STP750 OPERATOR'S MANUAL...
  • Page 2 BELGIE BELGIE BELGIE BELGIE BELGIE 1730 ASSE-MOLLEM 1730 ASSE-MOLLEM 1730 ASSE-MOLLEM 1730 ASSE-MOLLEM 1730 ASSE-MOLLEM ASSESTEENWEG 17 Tel. (32) 02-4528509+07 Tel. (32) 02-4528509+07 Tel. (32) 02-4528509+07 Tel. (32) 02-4528509+07 Tel. (32) 02-4528509+07 4040 Herstal 4 Avenue 9800 Deinze Kortrijkse Steenweg 400 Tel.
  • Page 3 Foreword Engine exhaust, some of its constituents, and certain vehicle components contain or emit chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. WARNING Foreword This manual provides information and procedures to safely operate and maintain this Wacker model.
  • Page 4 Nameplate / Typenschild / Placa de Identificación / Plaque signalétique A nameplate listing the Model Number, Item Number, Revision, and Serial Number is attached to each unit. Please record the information found on this plate so it will be available should the nameplate become lost or damaged. When ordering parts or requesting service information, you will always be asked to specify the model, item number, revision number, and serial number of the unit.
  • Page 5: Table Of Contents

    STP400 / STP750 Operating Information Table of Contents Safety Notes ................1A-2 Operating Safety ................ 1A-3 Service Safety ................1A-3 Technical Data................1A-4 Accessories ................1A-4 Application .................. 1A-4 Installation .................. 1A-5 Connection to Power Supply ............1A-5 Operation ..................1A-5 1.10 Use of Extension Cords ..............
  • Page 6: Safety Notes

    OPERATION Safety Notes This manual contains NOTES, CAUTIONS, and WARNINGS which must be followed to prevent the possibility of improper service, damage to the equipment, or personal injury. Notes: Notes contain additional information important to a procedure. CAUTION: Cautions provide information important to prevent errors which could damage machine or components.
  • Page 7: Operating Safety

    OPERATION Operating Safety Familiarity and proper training are required for the safe operation of equipment! Equipment operated improperly or by untrained personnel can be dangerous! Read the operating instructions and familiarize yourself with the location and proper use of all instruments and controls. WARNING NEVER use pump to pump low flash point fluids ALWAYS check power supply before connecting...
  • Page 8: Technical Data

    OPERATION Technical Data STP750 STP400 7650 7649 7648 7646 Index of Protection Rating Voltage Volts Frequency Phase Current Speed 2830 3430 2830 2830 rpm(1/min) Power 1 (750) 1 (750) 1/2 (400) 1/2 (400) Hp (W) Cable Length 33 (10) 33 (10)
  • Page 9: Installation

    OPERATION Installation Connection to Power Supply 1. Check voltage at installation site. It must match the This pump is equipped with a 3-wire cord rated for voltage requirements of the pump. Refer to “Technical outdoor use. Data” in this manual or the Dataplate attached to the pump.
  • Page 10: Operation

    OPERATION 1.10 Use of Extension Cords 1.12 Periodic Maintenance Extension cords should be used only when absolutely Before Use - Check cable and extension cords for wear necessary. When a long extension cord is used, a and damage. voltage loss occurs. The longer the cord the greater the voltage loss.
  • Page 11: Cleaning Impeller

    OPERATION 1.14 Cleaning Impeller If pump performance drops off, check for impeller wear and dirt accumulation in volute housing Remove three hex nuts from bottom of pump and remove strainer from pump. Remove nuts holding suction cover to pump and remove cover to expose impeller.
  • Page 12: Wiring Diagram

    OPERATION 1.16 Wiring Diagram STP750 7 RUN CAPACITOR MOTOR WINDINGS 8 WIRE NUT MOTOR PROTECTION SWITCH 9 CONNECTOR CONNECTOR STP 750 - 230V, 50 Hz 12.6 Ohm 3.9 Ohm 10 GROUND CONNECTION CENTRIFUGAL SWITCH 11 POWER CABLE START CAPACITOR STP 750 - 115V, 60 Hz 3.5 Ohm...
  • Page 13 EC - CONFORMITY CERTIFICATE EG-KONFORMITÄTS ERKLÄRUNG CE-CERTIFICADO DE CONFORMIDAD CERTIFICAT DE CONFORMITÉ DE LA CEE WACKER CORPORATION - MENOMONEE FALLS, WISCONSIN USA hereby certify that the construction equipment specified hereunder bescheinigt, daß das Baugerät certifica que la máquina de construcción atteste que le matériel 1.
  • Page 14 UNITED KINGDOM LONDON LEA ROAD Tel. (44)(01992) 707200 WALTHAM CROSS, HERTS EN9 1AW Washington Washington/Tyne N37 1LH Tel. (0191) 4 16 63 92 Warrington Winwick Quay, Warrington WA2 8RE Tel. (01925) 57 39 55 Worksop Worksop S81 7BE Tel. (01909) 48 45 06 Redditch Washford, Redditch B98 0DQ Tel.
  • Page 15 www.wackergroup.com UNITED STATES CORPORATE OFFICE MENOMONEE FALLS, WI 53052 N92 W15000 ANTHONY AVE. Tel. (262) 255-0500 CANADA MISSISSAUGA, ONT. L5T 2N6 160 ADMIRAL BLVD. Tel. (905) 795-1661 Calgary, Alta. T2H 2H9 #11, 6115-4 St. S.E. Tel. (403) 255-3336 St. Laurent, Quebec H4R 2C1 3526 Rue Ashby Tel.

This manual is also suitable for: