4.13 Strainer

4.14 Discharge Port

See Graphic: wc_gr001184
4.14.1 Remove the locknuts (b) which hold the port to the pump housing.
4.14.2 Lift the port off the studs and position it as desired. Always check the
4.14.3 Tighten the locknuts evenly. Torque them to 160 Nm (118 ft. lbs).
wc_tx000261gb.fm
NOTICE: DO NOT use a strainer with holes larger than the maximum
solid-size rating of the pump—50 mm (2 in.). DO NOT place the
strainer directly into mud or sand. Always keep the strainer suspended
in the liquid being pumped. Failure to follow the above directives may
cause pump damage.
The discharge port (a) can be rotated 360° to direct water flow in any
direction.
To rotate the elbow:
gasket and replace it if it is damaged.