8 Configuration
8.5

Menu structure: Overview installer settings

[A]
Installer settings
Language
System layout
Space operation
Domestic hot water (DHW)
Heat sources
System operation
Commissioning
Overview settings
INFORMATION
Solar kit settings are shown but are NOT applicable for this
unit. Settings shall NOT be used or changed.
INFORMATION
Depending on the selected installer settings, settings will
be visible/invisible.
Installer reference guide
72
[A.2]
System layout
Standard
Options
Capacities
Confirm layout
[A.3]
Space operation
LWT settings
Room thermostat
Operation range
[A.4]
Domestic hot water
Type
Disinfection
Maximum setpoint
SP mode
Weather-dependent curve
[A.5]
Heat sources
Backup heater
[A.6]
System operation
Auto restart
Preferential kWh rate
Pwr consumpt. control
Averaging time
Ext amb. sensor offset
Forced defrost
Emergency
[A.7]
Commissioning
Test run
UFH screed dryout
Air purge
Actuator test run
[A.2.1]
Standard
Unit type
Compressor type
Indoor software type
Backup heater steps
BUH type
Forced off contact
Unit control method
Number of LWT zones
Pump operation mode
Power saving possible
User interface location
[A.2.2]
Options
DHW operation
DHW tank type
Contact type main
Contact type add.
Digital I/O PCB
Demand PCB
External kWh meter
External kWh meter
DHW pump
External sensor
LAN adapter
[A.3.1]
Leaving water
Main
Additional
Delta T source
[A.3.2]
Room thermostat
Room temp. range
Room temp. offset
Ext. room sensor offset
Room temp. step
[A.3.3]
Operation range
Space heating OFF temp
Space cooling On temp
[A.4.4]
Disinfection
Disinfection
Operation day
Start time
Temperature target
Duration
[A.5.1]
Backup heater
Operation mode
Enable BUH step 2
Equilibrium temp.
[A.6.2]
Prefer. kWh rate PS
Allowed heaters
Forced pump OFF
[A.6.3]
Pwr consmp ctrl
Mode
Type
Amp. value
kW value
Amp. limits for DI
kW limits for DI
Priority
[A.2.2.6]
Digital I/O PCB
Ext. backup heat src
Solar kit
Alarm output
Bottom plate heater
[A.3.1.1]
Main
LWT setpoint mode
Temperature range
Modulated LWT
Shut-off valve
Emitter type
[A.3.1.2] Additional
LWT setpoint mode
Temperature range
[A.3.1.3] Delta T source
Heating
Cooling
RRLQ004~008CA + RHBH/X04+08CB
ROTEX HPSU low temperature Bi‑bloc
4P384979-1C – 2017.04

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RHBH04CB3V and is the answer not in the manual?

This manual is also suitable for:

Rrlq008cav3Rhbh08cb3vRhbh08cb9wRrlq004cav3Rrlq006cav3

Table of Contents