▪ Detailed step-by-step instructions and background information The user interface at a glance........... for basic and advanced usage 3.2.1 Buttons................ ▪ Format: Digital files on the ROTEX website. 3.2.2 Status icons ..............Space heating control..............Latest revisions of the supplied documentation may be available on 3.3.1...
Turns ON or OFF one of the controls (room temperature, Quiet mode is active. leaving water temperature, DHW tank temperature). MENU STRUCTURE/BACK Holiday mode is active or ready to be activated. Button lock mode and/or function lock mode is active. RGSQH10S18AA9W Operation manual ROTEX HPU ground 4P353880-1B – 2016.09...
1 Go to the room temperature home page (Room). Example: 2 Use to adjust the temperature. To change the mode from scheduled to preset value Prerequisite: User profile = Detailed. Operation manual RGSQH10S18AA9W ROTEX HPU ground 4P353880-1B – 2016.09...
1 Go to the DHW tank temperature home page (Tank). 3 Program the schedule for Monday: 60°C Result: is displayed. ▪ Use to select an entry. ▪ Use to change the value of an entry. RGSQH10S18AA9W Operation manual ROTEX HPU ground 4P353880-1B – 2016.09...
2 Select for which control you want to use a schedule. Example: [5.1] Room temperature. 3 Select for which operation mode you want to use a schedule. Example: [5.1.1] Heating. 4 Select a predefined or user‑defined schedule and press Operation manual RGSQH10S18AA9W ROTEX HPU ground 4P353880-1B – 2016.09...
▪ Outdoor unit relates to outdoor unit PCB which controls is valid. the compressor module of the ground source heat pump. RGSQH10S18AA9W Operation manual ROTEX HPU ground 4P353880-1B – 2016.09...
▪ Keep the area around the unit clean. Modulated LWT 0 (No) ▪ Keep the user interface clean with a soft damp cloth. Do NOT use any detergents. Leaving water temperature: Emitter type [A.3.1.1.7] Emitter type 0 (Quick) Operation manual RGSQH10S18AA9W ROTEX HPU ground 4P353880-1B – 2016.09...
Glossary DHW = Domestic hot water Hot water used, in any type of building, for domestic purposes. LWT = Leaving water temperature Water temperature at the water outlet of the heat pump. RGSQH10S18AA9W Operation manual ROTEX HPU ground 4P353880-1B – 2016.09...
Page 12