DESCRIPTION

3. ENERGY POWER AND GAS FLOW RATES

All of our appliances belong to Category II and are designed for gases from the second and
third groups.
The gas used can be either natural gas, propane or butane, depending on availability. Refer
to pages 24 – 26 for information about adapting your cooker or your hob to the various
types of gas.
The tables below summarise for each gas type and for each burner the heat flow rate
(energy power in kW, Maximum Heat Power) and the volume flow rate (in m3/hour) or
the mass flow rate (in kg/hour) of useful gas.
Burner
Gas hobs:
- large burner
- small burner
Hotplate
Large vaulted gas oven
(74/84 l)

4. POWER RATINGS FOR THE ELECTRICAL ELEMENTS

Large vaulted electric oven (74/84 litres, large volume) ......................................... 6 000 W
3 500 W oven floor + 2 500 W vault
Grill in large vaulted gas oven ................................................................................. 2 500 W
Baking stone ............................................................................................................ 3 000 W
Oven light ..................................................................................................................... 25 W
Ignition for small and large vaulted gas ovens .............................................................. 25 W
Automatic ignition for gas burners ............................................................................... 25 W
Warming cupboard, width: 450 mm ....................................................................... 1 750 W
Electric ceramic hob, Ø 145 mm .............................................................................. 1 200 W
Electric ceramic hob, Ø 195 mm (2 zones) .............................................................. 1 800 W
Round electric plate, Ø 180 mm .............................................................................. 2 000 W
Round electric plate, Ø 220 mm .............................................................................. 2 000 W
Electric hotplate ................................................................................................ 1 300 W
(small, dimensions: 284 x 476 mm)
Small "La Cornue" Teppan-Yaki .............................................................................. 1 600 W
Induction plates (2 burners) ................................................................................... 3 600 W
Nominal heat
flow
Volume flow rate (m
(Maximum
Natural Gas
Heat Power in
G20, 20 mbar
kW)
3
0,29
1,7
0,16
0,29
3
0,62
6,5
Installation Guide - "Cornuchef" Range
3
/ hour)
Mass flow rate (kg / hour)
Natural Gas
Propane
G25 20 mbar
G31 37 mbar
0,33
0,21
0,19
0,12
0,33
0,21
0,72
0,46

Energy power

Butane
G30 29 mbar
0,22
0,12
0,22
0,47
7