Table 3-6. Field Descriptions for the Two Wire Station Port and Channel Configuration Window
Field Name
Test Mode
[Signaling Bits]
(display only)
[Dial Mode]
(display only)
[Loopback]
(display only)
[Loop Detect]
(display only)
[Ring Cadence]
(display only)
®
8-Port Voice 2-Wire Station Module User Guide, Issue 1
PacketStar
255-700-261
Chapter 3 Configuring Ports and Channels Using the Console Interface
4 Select the values for the fields on this window from the values given in
Table 3-6.
Field Values
Default: None
QuietTime
F-1004Hz
Ab
Dtmf
NoLoopback
LoopStart
OneOnThreeOff
Description
The module is not in test mode.
Quiet Time is useful only if the line is not quiet
enough. If the line is noisy, the quiet time feature will
help you to determine whether the channel is noisy.
If noise is present on the line, then the channel is
defective.
Note: Do not select this value unless the line is noisy.
A 1004 Hz tone is used in troubleshooting a system
where a line is seized by bridging through a resistance
the tip and ring wires.
Signaling bits method supported is AB (two-bit signal-
ing).
Dual tone multi-frequency
The ports on this module cannot be set up for loop-
back.
Loop detection.
The pattern of the signaling—one second on and
three seconds off.