Encoder Housekeeping Commands

REGISTER INTERROGATION

Typing: RDS?8 returns the status of all flag and ID settings and the contents of static message
buffers to the screen. This was illustrated in section

ENCODER INITIALIZATION

The "initialize" command is invoked by typing: INIT8 . This is used to reestablish encoder
operation in the unlikely event of an internal software 'crash,' or for any other reason to restore
all the factory defaults
command only. It is not necessary to execute INIT8 prior to updating any encoder programming.

ENCODER RESET

Typing: RESET8 initiates a 'hardware reset' equivalent to turning the encoder off and back on
again. This reset command does not clear the registers of programming commands that have been
saved as described above.

FIRMWARE VERSION

Type: REV?8 for a display of the encoder's firmware version. This might prove important in
determining whether differences exist between SmartGen Mini encoders purchased at different
times.

NETWORK SETTINGS

Type: NET?8 for a display of the encoder's Network Settings, which include IP Address,
Subnet Mask, Gateway, DNS Server and DCHP Client. This is useful when infromation about
Network Settings is needed at a glance, instead of interrogate each one Network Parameter.
(see "Factory Defaults" on page
- 39 -
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com
"Power-Up" on page
43). INIT8 is an emergency recovery
35".