65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com
LOOP-THROUGH MODE
In the loop-through mode, the output of the stereo generator is cabled directly to the PILOT
OR MPX INPUT of the SmartGen Mini as shown in Figure below. Connect the RDS OR MPX
OUTPUT of the encoder to a composite/MPX wideband input of the FM exciter. When configured
for loop-through operation, the composite/MPX signal passes through the encoder with unity gain,
and with the RDS subcarrier added.
FM STEREO GENERATOR
MPX OUTPUT
SmartGen Mini
LAN
RDS OR MPX
PILOT OR MPX
OUTPUT
INPUT
FM EXCITER / TRANSMITTER
1
2
3
WIDEBAND INPUTS
Loop-Through Encoder Connection
- 28 -