ABB FCM2000 Operating Instruction page 73

Coriolis mass flowmeter for simultaneous measurement of mass, density and temperature
Table of Contents

Advertisement

7 Installation and Interconnections, Flowmeter Primaries and Converters
Interconnection Diagram: Ex-Design, ATEX, FM
1+ 2-
L
N
31 32 33 34 51 52 41 42 81 82
1)
PA
Model FCM2000-MC27B/C
1)
Supply power
• 100 V AC to 230 V AC terminals L, N, PA
• 24 V AC / 24 V DC terminals: 1+, 2-
Frequency 50/60 Hz
2)
Current output 1, selectable in software
Function: active
terminals: 31, 32, 0/4–20 mA,
≤ R
≤ 300
(0
L
3)
Current output 2, selectable in software
Function: passive
terminals: 33, 34, 4–20 mA, 0
Source voltage: 12 ≤ Uq ≤ 20 V
4)
Pulse output, passive
terminals: 51, 52
fmax: 5 kHz, pulse width 0.1 ms–2000 ms
Setting range: 0.001–1000 pulses/unit
0 V ≤ U
≤ 2 V, 16 V ≤ U
CEL
0 mA ≤ I
≤ 0.2 mA, 2 mA ≤ I
CEH
Ex"ib"/Ex"e" specifications for Model MC27B see Safety Specifica-
tions
Model FCM2000-MC26B/C
Anschlussraum
96 95 94 93 90 89 88 87 86 85
Fig. 30:
Interconnection Diagram Ex-Design, ATEX, FM
D184B111U02
FCM2000
Connection Area
2)
3)
4)
5)
)
≤ R
≤ 300
L
≤ 30 V
CEH
≤ 220 mA
CEL
91 92
PA
6)
PA
PA
5)
Contact output, passive
terminals: 41, 42
0 V ≤ U
≤ 2 V, 16 V ≤ U
CEL
0 mA ≤ I
≤ 0.2 mA, 2 mA ≤ I
CEH
6)
Contact input, passive
terminals: 81, 82
16 V ≤ U
„ON"
KL
0 V ≤ U
„OFF"
KL
R
= 2 kΩ
i
PA
PA
≤ 30 V
CEH
≤ 220 mA
CEL
≤ 30 V
≤ 2 V
73