ABB FCM2000 Operating Instruction page 62

Coriolis mass flowmeter for simultaneous measurement of mass, density and temperature
Table of Contents

Advertisement

Mass Flowrate
This menu can be used to measure the actual mass flowrate while in the simulation mode.
1. Enter a Mass Flowrate Value
The mass flowrate value for the simulation can be entered in percent. This menu is only displayed when mass
flowrate was selected. The allowable range of entries is -115 % to +115 %.
2. Density
This menu is used to define how the density is to be determined while in the simulation mode.
3. Enter a Density Value
The density value for the simulation can be entered. This menu is only displayed when density was selected.
The allowable range of entries is 0.3 to 3.7 g/cm
4. Temperature
This menu is used to define how the temperature is to be determined while in the simulation mode.
62
FCM2000
Qm
Measure
Qm
10.00%
Density
Enter
Density
1.00 g/cm3
Temperature
Enter
3
.
6 Converter
D184B111U02