MAB: Mark After Break time (micro sec) default
•
is 52
•
Channels: Number of channels to send in 1
Universe (default is 512)
Limitation: Same DMX port cannot be re-used in the
same profile.
Art-Net Stream:
"Send
destination address used when the stream is sending
data only (Unicast).
ESP Stream
: ENTTEC Show protocol DMX over
Ethernet stream (ESP). IP address is the destination
address used when the stream is sending data only.
Kinet Stream
: For example: You can connect Kinet
Stream to an Art-Net Stream to convert and output as
Art-Net. (Kinet stream is supported as input only)
Streaming ACN
: "IP address" is the destination
address used when the stream is sending data only
(default is disabled = 0.0.0.0)
IP
address":
is
the
DMX Generator
: Define your own custom DMX Channel
values and assign the selected ones.
Snapshot feature can be used to capture values from an
input stream. All modifications can be done using the
DMX Grid Page.
Merge
: HTP or LTP merge operator, drag as many lines
to the input node as you wish to merge
•
HTP Merge: Higher Takes Precedence - The
biggest DMX value will be output per channel
•
LTP Merge: Latest Takes Precedence - The latest
DMX value will be output per channel
Shifter:
can be used to shift a number of channels to
another spot in the INPUT DMX frame
Channels not defined will be left at 0 value
Example: To Shift 100 channels from 10 to 210:
Setup as "start listening at": 10 and, "start sending at":
210, "number of channels": 100
Switcher 1-2:
Controllable Switch operator, when the
trigger channel (Switch) is greater than the set value,
OUTPUT B is output, in other cases OUTPUT A is output .