2. Wired remote controller
2-1. Features
 High performance and compact size
 Simple function setting
Setting for selecting function of the air conditioner is performed by remote controller.
 Accurate and comfortable
Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body
of the wired controller.
Our system can correspond to various scenes.
This wired remote controller and the optional remote sensor allows flexibility in sensor location,
and suitable for all requirements.
Sensor part
• Various timer setup available (on, off, and weekly).
• Equipped with weekly timer as standard function. (Start/
stop function is twice per day for a week.)
• When setting up the timer, operation mode and tempera-
ture setup can be changed.
• When a failure occurs, the error code is displayed.
• Error history. (Last 16 error codes can be accessed.)
• The room temperature can be controlled by detecting the
temperature accurately with built-in thermo sensor.
Thermo sensor indicator
Control part for changing the thermo sensor
- 4 -