Fujitsu ARGA18FMTA Design & Technical Manual page 31

Table of Contents

Advertisement

4) Auto restart
Enable or disable automatic restart after a power interruption.
Function Number
40
* Auto restart is an emergency function such as for power outage etc.
Do not attempt to use this function in normal operation.
Be sure to operate the unit by remote controller or external device.
5) Room temperature sensor switching
(Only for wired remote controller)
When using the Wired remote controller temperature sensor, change the setting to "Both" (01).
Function Number
42
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller are active.
*Remote controller sensor must be turned on by using the remote controller.
6) External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
Function Number
46
7) Room temperature sensor switching (Aux.)
To use the temperature sensor on the wired remote controller only, change the setting to "Wired remote controller" (01). This function
will only work if the function setting 42 is set at "Both" (01).
Function Number
48
(  . . .Factory setting)
Setting Value
Setting Description
Enable
00
Disable
01
(  . . .Factory setting)
Setting Value
Setting Description
00
Indoor unit
01
Both
(  . . .Factory setting)
Setting Value
Setting Description
00
Operation/Stop mode
(Setting prohibited)
01
02
Forced stop mode
(  . . .Factory setting)
Setting Value
Setting Description
00
Both
01
Wired remote controller