5. Capacity compensation rate for pipe length and height
difference
Indoor unit is higher than outdoor unit
Indoor unit
Connection pipe
5-1. Model: AOGA30FBTAS
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Indoor unit is higher than
outdoor unit *1
Indoor unit is lower than
outdoor unit *2
Height difference H
1
*
H
Outdoor unit
5
15
-
10
-
7.5
-
5
1.027
0
1.027
-5
1.018
-7.5
-
-10
-
-15
-
- 65 -
Indoor unit is lower than outdoor unit
Outdoor unit
H
Indoor unit
Connection pipe
Pipe length (m)
7.5
10
15
-
-
0.988
-
0.996
0.988
1.000
0.996
0.988
1.000
0.996
0.988
1.000
0.996
0.988
0.992
0.988
0.980
0.988
0.984
0.976
-
0.980
0.972
-
-
0.964
2
*
20
30
0.979
0.963
0.979
0.963
0.979
0.963
0.979
0.963
0.979
0.963
0.972
0.955
0.968
0.951
0.965
0.948
0.956
0.940