4.3 Commissioning Board Software

4.3.1 Testing Links
The normal operation of communication links is the precondition for the board
software to operate normally. By querying alarms, the user can check whether the
OMLs between BTS3601C boards and OMU are normal, and whether the signaling
links between the boards and the main control Signaling Processing Unit (SPU) are
normal.
Besides, users can use the BTS3601C local/remote maintenance console to issue
commands to perform loopback test on the boards. In this way, the user can ensure
the normal operation of the communication links.
4.3.2 Processing Faults and Alarms
I. Description of alarms
The faults occurred on the modules during BTS3601C operation will be reported to
OMU in logs or alarms. After recording and processing, OMU will report them to
OMC.
The alarms generated by BTS3601C include the following levels: critical, major, minor
and notice.
What follows is the introduction to various module alarms items:
Common alarm
l
This alarm item includes the following alarms: 1. Board parameter configuration error
alarm; 2. Board temperature abnormal alarm; 3. Board communication link fault alarm;
4. Optical interface no signal alarm. 5. CUP overload alarm.
MBPB alarm
l
This alarm item includes the following alarms: 1. OML interrupted alarm; 2. Abis
signaling link fault alarm; 3. Satellite antenna feeder system fault alarm; 4. System
clock abnormal alarm; 5. Master clock out of lock alarm; 6, UNI link alarm; 7. E1/T1
link local alarm; 8. E1/T1 link remote alarm; 9. ASU fault alarm.
MTRB alarm
l
This alarm item includes the following alarms: 1. Receive channel over-activated
alarm; 2. Transmit channel clock unlocked alarm; 3. Hardware phase-lock loop
unlocked alarm; 4. Software phase-lock loop unlocked alarm; 5. I
alarm; 6. Digital down-converter alarm. Besides, the related alarms including fan,
power amplifier and MLNA alarms are also reported through MTRM.