Quinta pro series. suggested shematics with control and power wiring details

Advertisement

Quinta Pro multiple boiler HTG only using a low loss header outside,
Quinta Pro multiple boiler HTG only using a low loss header outside,
Multiple Quinta Pro boilers, HTG only using a low loss header,
weather/room compensation with iSense Pro controller.
weather/room compensation with iSense Pro controller.
outside weather/room compensation with iSense Pro controller
Outside sensor
on North
Outside sensor
facing wall
on North
230v
100m Max
facing wall
Supply
230v
100m Max
Supply
Multiple Quinta Pro boilers, heating and HTG and DHW using
Quinta Pro multiple boiler HTG and DHW using a low loss header,
a low loss header, outside weather/room compensation with
Quinta Pro multiple boiler HTG and DHW using a low loss header,
outside weather/room compensation with iSense Pro controller.
iSense Pro controller (DHW via multiple boilers)
outside weather/room compensation with iSense Pro controller.
(DHW via multiple boilers)
(DHW via multiple boilers)
Outside sensor
on North
Outside sensor
facing wall
on North
230v
100m Max
facing wall
Supply
230v
100m Max
Supply
28
Pump SH2
Pump SH1
Pump SH2
Pump SH1
Pump SH2
Pump SH1
Pump SH2
Pump SH1
Normal position for the iSense Pro
remote controllers or room sensors mounted
Normal position for the iSense Pro
in reference room within the building
remote controllers or room sensors mounted
in reference room within the building
iSense Pro
in wall
iSense Pro
mounted
in wall
box
mounted
230v
box
Supply
230v
Supply
Condensate
Pump B
Condensate
Gas
3 Port valve B
Flow
Pump B
Gas
3 Port valve B
Flow
Return
Return
Normal position for the iSense Pro
remote controllers or room sensors mounted
Normal position for the iSense Pro
in reference room within the building
remote controllers or room sensors mounted
in reference room within the building
iSense
Pro
in wall
iSense
mounted
Pro
in wall
box
mounted
230v
box
Supply
230v
Supply
Htg Flow sensor
Pump B
Htg Flow sensor
Pump B
3 Port valve
Condensate
Pump DHW1
3 Port valve
Condensate
Gas
Flow
Pump DHW1
Gas
Flow
Return
Bypass valve
Return
Bypass valve
100m Max
100m Max
Zone B
Optional Zone C
Zone B
Optional Zone C
Htg Flow sensor
Htg Flow sensor
Pump C
3 Port valve C
Pump C
3 Port valve C
QP 009
QP 009
QP 009
100m Max
100m Max
Zone B
Zone C
Zone B
Zone C
Htg Flow sensor
Pump C
Htg Flow sensor
DHW sensor
Pump C
3 Port valve
DHW sensor
3 Port valve
2 Port spring return valve
2 Port spring return valve
QP 009A
QP 009A
QP 009A