3.6
AIR-COOLED, IDENTIFICATION 40HP
Main Motor HP
40
40
NOTES:
1. ALLOW 4.00 FT. [1.25 METERS] MINIMUM CLEARANCE
AROUND MACHINE FOR ACCESS AND FREE CIRCULA-
TION OF AIR.
2. A FOUNDATION OR MOUNTING CAPABLE OF SUPPORT-
ING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO
MAINTAIN
THE
COMPRESSOR
REQUIRED. THE COMPRESSOR FRAME MUST BE LEV-
ELLED AND SECURED BETWEEN THE FRAME AND THE
FOUNDATION. NO PIPING LOADS MUST BE PERMITTED
AT EXTERNAL CONNECTIONS.
3. ALL DIMENSIONS ARE ±1/2" [12.7MM].
4. RECOMMENDED INCOMING CUSTOMER POWER SUP-
PLY IS SHOWN ON DRAWING.
5. IF DUCTWORK IS TO BE INSTALLED FOR COOLING AIR,
HIGH STATIC FAN MUST BE SELECTED. MAX ALLOW-
ABLE ADDITIONAL STATIC PRESSURE 0.4 IN H20 WITH
HIGH STATIC FAN.
Motor Type
ODP
TEFC
A1: SPACE REQUIRED TO OPEN DOORS
A2: SPACE REQUIRED TO OPEN STARTER PANEL
A3: CONTROLLER
A4: E-STOP
A5: AIR INLET
FRAME
LEVEL
IS
A6: EXHAUST AIR OUT
A7: CONTAINMENT PAN DRAIN
A8: INCOMING CUSTOMER POWER SUPPLY
A9: MOISTURE DRAIN CONNECTION 1/4"-18 NPT
A10: AIR OUT CONNECTION 1-1/2" NPT
Weight
CFM Cooling Air
1556 LBS/706 KG
2900 CFM
1613 LBS/732 KG
2900 CFM
Ø2.50[63.5]