1 4 .0 WARRAN T Y
ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the
original purchaser that this product is of merchantable quality and confirms
in kind and quality with the descriptions and specifications thereof. Product
failure or malfunction arising out of any defect in workmanship or material
in the product existing at the time of delivery thereof which manifests itself
within five years from the sale of such product, shall be remedied by repair
or replacement of such product, at ELECTROMATIC's option, except where
unauthorized repair, disassembly, tampering, abuse or misapplication has
taken place, as determined by ELECTROMATIC. All returns for warranty
or non-warranty repairs and/or replacement must be authorized by
ELECTROMATIC, in advance, with all repacking and shipping expenses
to the address below to be borne by the purchaser.
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT
LIMITED TO, THE WARRANTY OF MERCHANTABILITY AND
FITNESS FOR ANY PARTICULAR PURPOSE OR APPLICATION.
ELECTROMATIC SHALL NOT BE RESPONSIBLE NOR LIABLE FOR
ANY CONSEQUENTIAL DAMAGE, OF ANY KIND OR NATURE,
RESULTING FROM THE USE OF SUPPLIED EQUIPMENT, WHETHER
SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE, UPON OR
AFTER REPLACEMENT OR REPAIR, AND WHETHER OR NOT SUCH
DAMAGE IS CAUSED BY MANUFACTURER'S OR SUPPLIER'S
NEGLIGENCE WITHIN FIVE YEARS FROM INVOICE DATE.
Some State jurisdictions or States do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation may not apply
to you. The duration of any implied warranty, including, without limitation,
fitness for any particular purpose and merchantability with respect to this
product, is limited to the duration of the foregoing warranty. Some states
do not allow limitations on how long an implied warranty lasts but, not
withstanding, this warranty, in the absence of such limitations, shall extend
for five years from the date of invoice.
ELECTROMATIC Equipment Co., Inc.
600 Oakland Ave. Cedarhurst, NY 11516—USA
Tel: 1-800-645-4330/ Tel: 516-295-4300/ Fax: 516-295-4399
Every precaution has been taken in the preparation of this manual. Electromatic Equipment Co., Inc., assumes
no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of
information contained herein. Any brand or product names mentioned herein are used for identification purpos-
es only, and are trademarks or registered trademarks of their respective holders.
16
OI505-YSL
Ta ble of Cont e nt s
01.0
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02
1.1 Applications
0
2.0 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03
0
3.0 Contents of Complete Outfit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04
0
4.0 Overview of YSL-2000HD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05
4.1 LCD Display
4.2 Front Panel Key Functions
0
5.0 Installing Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06
6.0 Mearuring Yarn/Wire Speed & Length . . . . . . . . . . . . . . . . . . . . . . . . 07
007.0 Measuring Surface Speed or Length . . . . . . . . . . . . . . . . . . . . . . . . . . 09
0
8.0 Using Optional Surface Speed Wheels . . . . . . . . . . . . . . . . . . . . . . . . . 10
9.0 Measuring RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
9.1 Contact Operation
9.2 Non-Contact Operation
10.0 Memory System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
11.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
12.0 Spare Parts & Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
13.0 Removing the Protective Rubber Shell . . . . . . . . . . . . . . . . . . . . . . . . . 15
14.0 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the YSL-2000HD and is the answer not in the manual?

Questions and answers

Summary of Contents for Check-line YSL-2000HD

  • Page 1 ELECTROMATIC. All returns for warranty 4.0 Overview of YSL-2000HD ........05 or non-warranty repairs and/or replacement must be authorized by 4.1 LCD Display...
  • Page 2 Non-Contact Tachometer gauge forward and out of the shell. Without either Measuring Head installed, the YSL-2000HD can be used as a 3. Replace the shell by sliding the gauge Non-Contact Tachometer. In this operating mode, a small piece of reflective bottom first into the large center opening, tape is applied to the rotating element (wheel, shaft, etc.).
  • Page 3 1 1 .0 SPECI FI CAT I ON S 2 .0 SAFET Y PRECAU T I ON S All operators should wear safety goggles when using this or any other Measuring Ranges – rpm tachometer. Failure to do so could result in serious injury! Optical 1 –...
  • Page 4 3 .0 CON T EN T S OF COM PLET E OU T FI T 1 0 .0 M EM ORY SY ST EM The YSL-2000HD is supplied with the following accessories in a foam-fitted, The YSL-2000HD is supplied with...
  • Page 5 3. Select the Non-Contact RPM mode by pressing the MODE key until the rpm symbol appears in the top left corner of the LCD display 4. Aim the YSL-2000HD at the target using 4.1 LCD Display the red visible light beam for alignment assistance.
  • Page 6 5 .0 I N STALLI N G BAT T ERI ES 9 .0 M EASU RI N G RPM 9.1 Contact Operation - RPM 1. Turn the gauge over and locate the battery compartment. You do not have to remove the rubber shell.
  • Page 7 6 .0 M EASU RI N G YARN /WI RE SPEED & LEN GT H 8 .0 U SI N G OPT I ON AL-SI Z ED SU RFACE SPEED WH EELS 1. Install the Slide-on Measuring Head for The following wheels can be used with the YSL-2000HD Yarn/Wire Speed& Length. 1.2"...
  • Page 8 6. Insert the filament between the outer 7 .0 M EASU RI N G SU RFACE SPEED OR LEN GT H “wrapper” roller and measuring wheel letting it contact the flat surface on the Install the Slide-on Contact Adapter. top of the Wrapper Roller Arm. Rotate the instrument counter-clockwise approximately 90 degrees (1/4 turn).