Installation
The panels of the adjacent cabinets must be made of heat-
resistant material. In particular, cabinets with a veneer exterior
must be assembled with glues which can withstand temperatures
of up to 100°C.
In compliance with current safety standards, contact with the
electrical parts of the oven must not be possible once it has been
installed.
All parts, which ensure the safe operation of the appliance, must be
removable only with the aid of a tool.
In compliance with the current safety standards, contact with the
electrical parts of the oven must not be possible once it has been
installed. To fasten the oven to the cabinet, open the door of the
oven and attach it by inserting the 4 wood screws into the 4 holes
located on the perimeter of the frame.

Electrical connection

When connecting the cable directly to the mains, connection to the
electricity supply must be made by an authorised person in
accordance with the Wiring Rules AS/NZS3000. The installation
must include a suitable isolating switch with a minimum contact
opening of 3mm between the appliance and the mains. The
isolating switch should be sized according to the load on the data
label and should comply with current regulations (the earth wire
should not be interrupted by the circuit breaker).
There must be a means for disconnection from the supply mains
having a contact separation in all poles that provide for full
disconnection under overvoltage category III conditions
incorporated in the fixed wiring in accordance with the wiring rules.
The supply cable should be positioned so that it does not reach a
temperature of more than 50℃ along its entire length.
Before making the connection check that:
· The switch, wiring and electrical system can support the
appliance load (see data plate);
· The power supply system has an efficient earthing connection
which complies with the provisions of current regulations;
· The power outlet or omnipoar circuit-breaker is easily accessible
once the cooker has been installed.