5.3 Inserting / removing the battery

CAUTION
Electrical hazard. Dirty contacts may cause a short circuit.
▶ Check that the contacts on the battery and on the tool are free from foreign objects before inserting
the battery.
CAUTION
Risk of injury. If the battery is not fitted correctly it may drop out and fall.
▶ Check that the battery is securely seated in the tool so that it cannot drop out and fall, thereby
presenting a hazard to other persons.
1. Push the battery in until it engages securely.
◁ The rotating laser is ready to be switched on.
2. Press the release button and hold it in this position.
3. Pull the battery out.

5.4 Switching the rotating laser on and working in the horizontal plane

Note
Check the accuracy of the rotating laser before using it for important tasks, especially if it has been
dropped or subjected to unusual influences or impacts, or after long periods of storage.
1. Mount the rotating laser on a suitable holder or bracket.
2. Press the
button.
◁ The auto-leveling LED flashes green.