Day: The operating mode brings the zone to the desired
temperature set for Day temp. cooling, regardless of the
time periods that you have set in the time programme.
5.3.3
Setting the Ventilation operating mode
The operating instructions for the ventilation unit explain how
the ventilation unit works with the ventilation levels.
Op. mode → Ventilation
You can use this function to define how the ventilation
unit operates during ventilation.
Auto: The operating mode controls the air exchange via
the set ventilation level Max. vent. stage: Day in the set
time periods that you have defined in the time programme.
The set ventilation level Max. vent. stge: Night is effective
outside of the time periods.
If air-quality sensors are connected to the ventilation unit, the
ventilation unit varies the ventilation levels:
If the air quality is good, the ventilation unit works at a
lower ventilation level than the one that is set.
If the air quality is poor, the ventilation unit works at a
higher ventilation level. However, the ventilation unit can-
not exceed the Max. vent. stage: Day and Max. vent.
stge: Night ventilation levels that are set.
Day: The operating mode constantly controls the exchange
of air using the value that you set in the Max. vent. stage:
Day ventilation level.
Set-back: The operating mode constantly controls the ex-
change of air using the value that you set in the Max. vent.
stge: Night ventilation level.
5.3.4
Setting the operating mode for hot water
generation
Op. mode → Domestic hot water
You can use this function to specify how the system op-
erates during hot water generation.
off: Hot water generation is switched off and the frost protec-
tion function is activated.
Auto: The operating mode brings the hot water generation to
the desired temperature set for Domestic hot water in the
time periods that you have set in the time programme.
Day: The operating mode brings the hot water generation
to the desired temperature set for Domestic hot water, re-
gardless of the time periods that you have set in the time
programme.
5.3.5
Operating mode for circulation
The operating mode for circulation always corresponds to
the operating mode for hot water. You cannot set a different
operating mode.
0020255037_00 multiMATIC Operating instructions
Operating and display functions 5
5.4

Advanced functions

The advanced functions can be activated directly from any
operating mode using the right-hand selection button Op.
mode. If the heating installation is equipped with more than
one zone, the activated advanced function only applies for
the zone that was preset by the competent person.
If more than one zone is activated, you can set a separate
advanced function for each zone using the left-hand selec-
tion button Menu → Basic settings.
The path details given at the start of each advanced function
description indicate how you can access this advanced func-
tion in the menu structure.
5.4.1
Manual cooling
Op. mode → Manual cooling
If the outside temperature is high, you can activate the
Manual cooling advanced function. You define for how
many days you want to activate the advanced function. If
you activate Manual cooling, you cannot use the heating
function at the same time. The Manual cooling function
takes priority over the heating function.
The setting applies for as long as the advanced function is
active. The advanced function is deactivated if the days that
are set have elapsed or if the outside temperature falls below
4 °C.
If you want to set the temperature separately for more than
one zone, you can set these temperatures using the Desired
temperatures function.
5.4.2
1 day at home
Op. mode → 1 day at home
Menu → Basic settings → Operating mode → ZONE1 → 1
day at home
If you spend a weekday at home, activate the 1 day at
home advanced function. The advanced function activ-
ates the Automatic mode mode for one day with the set-
tings for Sunday, as set in the Time programmes func-
tion.
The advanced function is automatically deactivated after
24:00 hours or you can cancel the advanced function first.
The heating installation will then return to the pre-set operat-
ing mode.
5.4.3
1 day away from home
Op. mode → 1 day away from home
Menu → Basic settings → Operating mode → ZONE1 → 1
day away from home
If you are only away from home for one day, activate
the 1 day away from home advanced function. The ad-
vanced function brings the room temperature to the Set-
back desired temperature.
Hot water generation and circulation are switched off and the
frost protection is activated.
The advanced function is automatically deactivated after
24:00 hours or you can cancel the advanced function first.
The heating installation will then return to the pre-set operat-
ing mode.
Ventilation is activated and works at the lowest ventilation
level.