Connecting The Ac Power Cable To The Chiller Unit - NEC NC1700L Installation Manual

Dlp cinema projector, chiller unit
Hide thumbs Also See for NC1700L:
Table of Contents

Advertisement

2-7-2. Connecting the AC Power Cable to the Chiller Unit

Preparation: Phillips head screwdriver, flatblade screwdriver (No.2)
WARNING
Check that the AC power supply is disconnected before connecting the power cable to the chiller unit. If connected, this
may cause fire or shock.
1
Remove the cover plate of the chiller unit.
Remove the screws (four locations), and remove the cover.
2
Check that the AC power cable can fit through the cable holes.
Fit the power cable through the cable holes.
When the cable is too thick, replace the holding clip for AC power cable with that included in the accessories.
3
Insert the L/N wire of the AC power cable into the connecting terminal, and tighten the screws.
Insert the AC power cable crimp terminals over the connecting terminal securement holes, and tighten the screws
with a Phillips head screwdriver.
WARNING
Firmly tighten the AC power cable to the connecting terminal. After tightening all screws, check that all power cables are
properly tightened and in place. If the screws are not firmly tightened, this may cause serious personal injury or even death.
Setting Up Your Projector and Chiller Unit
69

Hide quick links: