Table of Contents

Advertisement

Testing

Test Procedures:
Test the Carbon Monoxide detector operation
after the motorhome has been in storage,
before each trip and at least once a week
during use. Test by holding the Test/Reset
button in until the alarm sounds four beeps and
the indicator lamp is steady red. Six seconds
later the alarm will again beep four times and
the indicator light goes steady green.
Peak Level Memory:
The CO detector has the capability to
remember the level of Carbon Monoxide that
activated the alarm.
Press the Test/Reset button for less than one
second and observe the visual and audible
signals.
One beep and one green flash indicate
z
memory is clear.
Two beeps and two red flashes indicate
z
less than 100 ppm.
Three beeps and three red flashes
z
indicate less than 200 ppm.
Four beeps and four red flashes indicate
z
greater than 200 ppm.
NOTE:
Memory is erased when power is
disconnected for 15 seconds.
46
Cleaning & Maintenance
Use a vacuum cleaner to remove dust or
any other buildup on the detector. Do not
wash. Wipe the detector with a damp cloth
and dry with a towel. Do not open the detector
for cleaning. Do not paint the detector. It
is recommend that the Carbon Monoxide
detector be replaced every five years.
The CO detector has no user service parts.
If there is a problem with the detector refer
to an authorized service center. Do not
remove power.
INSPECTION:
Test the CO detector weekly and at the
020155e
beginning and end of each trip.
FIRE ExTINgUIsHER
A fire extinguisher is located near the entry
door. Please read the operating instructions
printed on the fire extinguisher.
020283b
2016 Admiral
Use the PASS method:
Pull the pin. Hold extinguisher upright.
Aim at the base (bottom) of the fire and stand
six feet away.
Squeeze the lever to discharge the agent.
Sweep the spray side to side until fire is
totally extinguished.
If there is any doubt on how to operate the
fire extinguisher practice using it. Replace or
recharge the extinguisher immediately after
use.
Maintenance
Inspect the fire extinguisher at least once
a month. Inspect more frequently if the
extinguisher is exposed to weather or possible
tampering. Do not test the extinguisher by
partially discharging. Internal pressure will
escape and the fire extinguisher will need to be
replaced.
WARNING:
Road vibration will cause
extinguisher powder to
compact and may cause
extinguisher malfunction.
Invert and shake
extinguisher monthly.
020261

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents