Dru Saxo SL 80 Instructions For Installation Manual

Hide thumbs Also See for Saxo SL 80:

Advertisement

Quick Links

Saxo SL 80
Instructionsforinstallation
(GB/IE)
Pleaseretainthisdocumentcarefully
U K

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Saxo SL 80 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dru Saxo SL 80

  • Page 1 Saxo SL 80 Instructionsforinstallation (GB/IE) Pleaseretainthisdocumentcarefully...
  • Page 2 8.2 G aspressure/pre-pressure 8.3 I gnitionpilotburnerandmainburners 8.4 F lameimage 9.  M aintenance 10.  D elivery 11.  M alfunctions Appendix1 P artsincludedwiththedelivery Appendix2  T echnicaldata Appendix3 P arts Preface DRU,amanufacturerofgasheatingappliances,developsandproducesproductsthatcomplywiththehighestqua- lity,performanceandsafetyrequirements. Thisguaranteesthattheuserwillbeabletoenjoyusinghisproductformanyyearstocome. ThisappliancehasaCEmarking,whichmeansthatitcomplieswiththeessentialrequirementsoftheEuropeangas appliancedirective. Asaninstaller,youmustbecompetentinthefieldofatmosphericgasheating. Twomanualsaresuppliedwiththeappliance:theinstallationmanualandtheusermanual. Theinstallationmanualwillgiveyoutheinformationyouneedtoinstalltheapplianceinsuchawaythatitwillope- rateproperlyandsafely. Thismanualdiscussestheinstallationoftheapplianceandtheregulationsthatapplytotheinstallation.Inaddition, youwillfindtechnicaldatafortheapplianceandinformationonmaintenance,anymalfunctionsthatmightoccur andtheirpossiblecauses.
  • Page 3: I Ntroduction

    200 cm ➠ only use the flue gas discharge / combustion air supply system supplied by DRU; ➠ mount the appliance using the wall brackets supplied;...
  • Page 4: I Nstructions

    -  B oxcontainingparts;youwillfinditinthecombustionchamber. Remove the box containing parts from the combustion chamber. ➠ Inappendix1/table4youcanseewhichpartsyoushouldhaveafterremovingthepackaging. Contact DRU Service if you do not have all the parts after you finished removing the packaging. ➠ Dispose packaging in accordance with local regulations. ➠...
  • Page 5: P LacingTheAppliance

    80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n Thefollowingrequirementsapplytothegasconnection: -  u seagaspipewiththecorrectdimensions,sothatnopressurelosscanoccur; -  t hegastapshouldhavetheCEmarking; -  y oushouldalwaysbeabletoreachthegastap.
  • Page 6 80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n 38c-1263 Fig. 2 Tot. min. Tot. min. 200 cm 200 cm 38c-1265 Fig.
  • Page 7: F LueGasDischarge/CombustionAirSupplySystem

    Thepassagetotheoutsidecanbemadewithawallduct(seesection6.5.2)oraroofduct(seesection6.5.3). Ifnecessary,youcanalsouseanexistingdischargechannel(seesection6.5.4). Caution Only use the concentric system supplied by DRU (Ø100 / Ø150 mm). This system has been tested together with the ap- pliance. DRU cannot guarantee a proper and safe operation of other systems. - For connecting to an existing chimney fl ue you should only use the installation set supplied by DRU.
  • Page 8 80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n Afb. 4a Afb. 4b - Use heat-resistant isolation material when passing through combustible material; - The rosette (mounting inner plate) of the wall duct is too small to seal the Ø...
  • Page 9 80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n Examples Toclarify,wewillgive2examplestodeterminetheallowabilityofaconcentricsystemandtheconditionsforsetting theappliance. InTable1theroutetobefollowedisindicatedbyarrows.Theresultisindicatedbyaboxwitharedframe. Example 1 1) 2 bends 2)  3 metershorizontal 3) 8 metersvertical/sloping →Constructionofthisconcentricsystemisallowed.
  • Page 10: P LacingTheChimneyBreast

    Itispossibletoconnecttheappliancetoanexistingchannel. A flexible SS pipe is placed in the chimney for discharging flue gases. The surrounding space is used to supply combustionair. Thefollowingrequirementsapplywhenconnectingtoanexistingchimneyflue: -  o nlyallowedwhenusedincombinationwiththespecialDRUchimneyinstallationset.Theinstallationregulation isalsosupplied. -  t hedimensionsshouldbeatleast150x150mm; -  t heverticallengthhasamaximumof12meters; -  t hehorizontallengthhasamaximumof3meters;...
  • Page 11 When using bricks, we recommend bricks with a thickness of 70 to 100 mm; !Tip - You should preferably apply the ventilation holes on both sides of the chimney breast: you can use DRU ventilation elements. Check whether the concentric system is placed correctly. ➠...
  • Page 12: P LacingTheControlBox

    80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n !Caution Do not allow the mantel iron to rest on the fl anges of the build-in frame. Mount the threaded rod on the corner of the mantel iron (1), using the nuts.
  • Page 13: A DjustingTheAppliance

    80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n Caution - Avoid kinks in the pipes; - Tighten the fl exible hose and the aluminium pipe until they are gastight; - First tighten thermocouple 1 by hand and - then tighten it a quarter turn using a suitable spanner.
  • Page 14 80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n Afb. 10b 6.8.3 P rimary aeration of the burners Caution Adjusting the primary aeration only applies to appliances used in Belgium. Whenthetraysurroundingtheburnersisremoved,youcanseethethrottlerings(PaandPb)thataremountedon thepipesthatarefi  xedtotheburners(burnerpipes);seefi g.
  • Page 15 80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n Afb 12a Afb 12b Afb 12c Afb 12d 6.9 P lacing wood set Theapplianceissuppliedwithawoodset.
  • Page 16 80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n Afb 13 Afb 14 Afb. 15 Afb. 16a Afb.
  • Page 17 80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n Afb. 16c Afb. 16d Afb. 16e Afb. 16f...
  • Page 18 80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n Afb. 16g Afb. 16h Afb. 16i Afb. 16j...
  • Page 19: P Anes

    6.10.1.2 P lacing the front pane Placing the front pane will take place in reverse orderoftheremovalproceduredescribedabove. !Caution - The DRU logo should be at the bottom right corner; - Do not screw the parkers on too tight, to prevent breaking and/or slipping: tight=tight.
  • Page 20: W IrelessRemoteControl

    80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n Afb. 17d Afb. 17e W ireless remote control Theapplianceissuppliedwithawirelessremotecontrol. Ignition,controllingthefl  ameheightandswitchingoffareperformedbyaremotecontrolthatoperatesareceiver inthecontrolbox.
  • Page 21: F InalCheck

    80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n !Caution - Avoid a short circuit between the batteries and metal objects/parts; - Observe the “+”...
  • Page 22: F LameImage

    80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n 1)Ifthemainburnersdonotburn: Check if button A on the gas control is in the position ON; ➠...
  • Page 23: M Aintenance

    80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n 9. M aintenance Onceayeartheapplianceshouldbechecked,cleanedand,ifnecessary,repairedbyacompetentinstallerinthefield ofatmosphericgasheating. Checkatleastwhethertheapplianceisworkingproperlyandsafely. Caution - Close the gas tap when performing maintenance work; - Check the gastightness after repair;...
  • Page 24: M Alfunctions

    80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n 11. M alfunctions Inthefollowingtableyouwillfindanoverviewofmalfunctionsthatmightoccur,thepossiblecausesandthereme- dies Table 3: diagnosis of malfunction Problem Possible cause Remedy A.  N otransmission...
  • Page 25 80 - s a x o s l i n s t r u c t i o n f o r i n s ta l l at i o n Table 3: diagnosis of malfunction Problem Possible cause Remedy F.  E lectronicskeep 1.  R eceiverisdamaged.
  • Page 26: Appendix1 P ArtsIncludedWithTheDelivery

    s a x o s l Appendix 1 P arts included with the delivery Inthefollowingtableyoucanfindthepartsthataresuppliedwiththeappliance. Table 4: Parts included with the delivery Part Quantity Order number Woodset 806748 Controlbox 26280 Manualcontrolbox 957.577.06 Installationmanual 959.010.01 Usermanual 958.010.00 Decorativestripleft/right 38724384 Decorativestripbelow 38724569 Settingtemplateforbaffle 38714582 Baffle 38741476 WedgeboltsM8x140x50 509330 HexagonalnutM8 521308 Sealingring8.4mm 525070 Spareparkersformountingthepanes 519419 Socketspanner8mm 790811...
  • Page 27 s a x o s l Notes ........................................... . .
  • Page 28 DRU Verwarming B.V. The Netherlands Postbus1021,NL-6920BADuiven Ratio8,NL-6921RWDuiven...

This manual is also suitable for:

Scenic sl 80

Table of Contents