Dru G20 Instructions For Installation Manual

Atmospheric gas heating appliance

Advertisement

Solo
G20/G25

Instructions for installation

Please retain this document carefully
95900605 UK Install_G20.indd 1
95900605 UK Install_G20.indd 1
(GB / IE)
U K
2-2-10 12:55
2-2-10 12:55

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dru G20

  • Page 1: Instructions For Installation

    Solo G20/G25 Instructions for installation (GB / IE) Please retain this document carefully 95900605 UK Install_G20.indd 1 95900605 UK Install_G20.indd 1 2-2-10 12:55 2-2-10 12:55...
  • Page 2: Table Of Contents

    Appendix 3 Parts Preface DRU, a manufacturer of gas heating appliances, develops and produces products that comply with the highest qua- lity, performance and safety requirements. This guarantees that the user will be able to enjoy using his product for many years to come.
  • Page 3: Introduction

    Manufacturer: DRU Haardkachels B.V. Postbus 37, NL-6660 AA Elst Industrieweg Oost 11, NL-6662 NE Elst hereby declares that the design and construction of DRU’ atmospheric gas heating appliance comply with the es- sential requirements of the Gas Appliance Directive. Product:...
  • Page 4: Instructions

    Check whether the appliance is suitable for the type of gas and the gas pressure used on site. !Caution By default, the appliance is set up for gas type G25. If you connect the appliance to gas type G20, you should change the primary aeration.
  • Page 5: Placing The Appliance

    S O L O I N S T R U C T I O N F O R I N S TA L L AT I O N Proceed as follows, when reconstructing to a back connection: ➠ Take aluminium bend C from the air inlet stub; see Fig.
  • Page 6 I N S T R U C T I O N F O R I N S TA L L AT I O N Caution - Only use the concentric system supplied by DRU (Ø100 / Ø150 mm). This system was tested in combination with the appliance.
  • Page 7 ➠ Make sure the wall duct has the right dimensions. !Caution - For G20, the primary aeration burner must be adjusted. Make sure that the right insertion length is maintained; - Place the wall duct with the groove/folded seam at the top;...
  • Page 8 2) 4 meters horizontal 3) 9 meters vertical/sloping → Construction of this concentric system is not allowed. Table 1: Conditions for setting appliance with roof duct G20/25 Total number of Total number of meters vertical and/or sloping pipe length meters horizontal...
  • Page 9 The following requirements apply when connecting to an existing chimney fl ue: - only allowed when used in combination with the special DRU chimney installation set. The installation regulation is also supplied; - the dimensions should be at least 150 x 150 mm;...
  • Page 10: Connecting Gas

    S O L O I N S T R U C T I O N F O R I N S TA L L AT I O N 6.7 Connecting gas Use the following procedure when connecting the gas, see section 6.3, Gas Connection: ➠...
  • Page 11: Placing Wood Set

    S O L O I N S T R U C T I O N F O R I N S TA L L AT I O N Fig. 8 Fig. 9 Fig. 10 Fig. 11 6.9 Placing wood set The appliance is supplied with a wood set.
  • Page 12 S O L O I N S T R U C T I O N F O R I N S TA L L AT I O N Fig. 12 Fig. 13 95900605 UK Install_G20.indd 12 95900605 UK Install_G20.indd 12 2-2-10 12:56 2-2-10 12:56...
  • Page 13 S O L O I N S T R U C T I O N F O R I N S TA L L AT I O N Fig. 14 Fig. 15 95900605 UK Install_G20.indd 13 95900605 UK Install_G20.indd 13 2-2-10 12:56 2-2-10 12:56...
  • Page 14: Operation

    S O L O I N S T R U C T I O N F O R I N S TA L L AT I O N 6.10.1 Removing the pane Proceed as follows, to remove the pane: ➠ Push the frame up at the bottom;...
  • Page 15: Final Check

    S O L O I N S T R U C T I O N F O R I N S TA L L AT I O N Final check In order to check whether the appliance is working properly and safely, you must perform the following checks before the appliance is used.
  • Page 16: Maintenance

    S O L O I N S T R U C T I O N F O R I N S TA L L AT I O N Maintenance Once a year the appliance should be checked, cleaned and, if necessary, repaired by a competent installer in the fi eld of atmospheric gas heating.
  • Page 17: Malfunctions

    S O L O I N S T R U C T I O N F O R I N S TA L L AT I O N 11. Malfunctions In the following table you will fi nd an overview of malfunctions that might occur, the possible causes and the reme- dies Table 3: Diagnosis of malfunctions Problem...
  • Page 18: Appendix 1 Parts Included With The Delivery

    S O L O I N S T R U C T I O N F O R I N S TA L L AT I O N Appendix 1 Parts included with the delivery In the following table you can fi nd the parts that are supplied with the appliance. Table 4: Parts included with the delivery Part Quantity...
  • Page 19 S O L O I N S T R U C T I O N F O R I N S TA L L AT I O N Notes ........................................... . .
  • Page 20 95900605 UK Install_G20.indd 20 95900605 UK Install_G20.indd 20 2-2-10 12:56 2-2-10 12:56...

This manual is also suitable for:

G25Solo g20Solo g25

Table of Contents