INSTALLATIEVOORSCHRIFT EN GEBRUIKERSHANDLEIDING
INSTRUCTIONS FOR INSTALLATION AND OPERATIONS
INSTRUCTIONS D'INSTALLATION ET MODE D'EMPLOI
INSTALLATIONSVORSCHRIFT UND GEBRAUCHSANWEISUNG
ROMANO
Bewaar dit document zorgvuldig
Please retain this document carefully
Conservez soigneusement cette notice
Bewahren Sie dieses Dokument sorgfältig auf
DRU VERWARMING B.V.
HOLLAND
957.582.01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Romano and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dru Romano

  • Page 1 INSTALLATIEVOORSCHRIFT EN GEBRUIKERSHANDLEIDING INSTRUCTIONS FOR INSTALLATION AND OPERATIONS INSTRUCTIONS D’INSTALLATION ET MODE D’EMPLOI INSTALLATIONSVORSCHRIFT UND GEBRAUCHSANWEISUNG ROMANO Bewaar dit document zorgvuldig Please retain this document carefully Conservez soigneusement cette notice Bewahren Sie dieses Dokument sorgfältig auf DRU VERWARMING B.V. HOLLAND 957.582.01...
  • Page 2 1064 38c-1097 Romano...
  • Page 3 100 mm an das Gerät angeschlossen wird. • Es ist nicht erlaubt ein eingebautes Gerät in Isolationsmaterial zu wickeln. • Bevor Sie das Gerät zum ersten Mal benützen sollten Sie das Glas reinigen. Dies um einbrennen von eventueller Schmutz im Glas zu vermeiden. Romano...
  • Page 4: Table Of Contents

    • This appliance has been manufactured and tested by DRU verwarming BV of The Netherlands with utmost care. • Subject to the conditions set out on this card DRU guarantees the proper operation of this vented room heater to the original purchaser for a period of one year after date of purchase.
  • Page 5: Foreword

    50 cm away from the heater. • Beware! Touching hot parts of the heater can cause burns We would like to thank you for buying this DRU product. and blisters! Our products have been designed and produced to meet •...
  • Page 6: Fitting The Appliance

    • Dismantle the outlet connector (4) by removing the 2 self- tapping screws (5), (fig.2). • First slide the flue pipes into the chimney and fix them to leave sufficient room underneath to slide the casing into the fireplace or chimney breast. fig. 2 fig. 1 fig. 3 Romano...
  • Page 7: Mantel Iron

    INSTRUCTIONS FOR INSTALLATION Mantel iron Adjusting for G25 natural gas A good means of supporting the brickwork above the Ex works the appliance is adjusted for use with G20 hearth surround is an iron mantel: a steel angle section natural gas.The primary aeration of the burner tray has a (e.g.
  • Page 8: Positioning The Logs Or White Carrara Stones

    (fig. 8). Once the logs or stones are in position, the • Position the logs (fig.9) as illustrated (fig.10). glass pane can be replaced and fixed with the glass strip (1) and the 5 self-tapping screws (2) (fig.1). fig. 8 Romano...
  • Page 9 INSTRUCTIONS FOR INSTALLATION fig. 9 fig. 10...
  • Page 10: Mounting The Frame And Front

    Fit the frame to the interior with the 4 self-tapping screws (13), ( figs. 13 and 14). Hang the front onto the interior with the hooks (14) (figs. 15 and 16). fig. 11 fig. 12 fig. 13 fig. 14 fig. 15 38c-1101 SECTION A-A fig. 16 Romano...
  • Page 11: Remote Control

    INSTRUCTIONS FOR INSTALLATION Remote control Replacing the batteries in the receiver Remote control is supplied as a standard accessory. • Open the door at the front. The heater has a freely adjustable. Batteries, with a life • Take the receiver and open the cover. expectancy of approximately one year, feed the electrical The batteries are under that cover.
  • Page 12: Operating Instructions

    Do not force the button, as this may result in damage to the mechanism. Fig. 18b Romano...
  • Page 13: Changing The Elements

    CONVERSION INSTRUCTIONS Fig. 18c Fig. 19 Changing the elements electrode. Unscrew the thermocouple from the gas control block. 1. Outlet connector (fig. 18b and 18c) Remove the oxypilot by undoing the 2 screws (18) Break and remove the semi-circle (23) of the connection and fit the new oxypilot.
  • Page 14: Replacing The Base Set And Burner Unit

    GENERAL NOTES Replacing the base set and burner unit use corrosive or abrasive substances to clean the casing. Any damage to the coating, caused by things put on or • Apply the new type plate. against the casing for example, is not covered by the •...
  • Page 15: Lighting The Heater For The First Time

    GENERAL NOTES Extra protection These problems can be avoided by ensuring that the room the heater is in is properly ventilated. A good guideline for This heater meets the normal safety standards regarding ventilation is: surface temperatures, but physical contact with heated New buildings : 3.24 m / hour per m...
  • Page 16 TECHNISCHE GEGEVENS,TECHNICAL DATA, DONNÉES TECHNIQUES,TECHNISCHEN DATEN Romano Gassoort,Type of gas, Sorte de gaz, Gassorte Voordruk, Pression, Pression, Gasdruck mbar Branderdruk, Burner pressure, Pression de brûleur, Brennerdruck mbar Nom. Belasting (Hs), Nom. Load (Hs), Puissance calorifique (Hs), Nom. Belastung (Hs) 6,90 Nom.
  • Page 18 Romano...