BLUE SKY IPN ProRemote Installation And Operation Manual page 8

Ipn network compatible charge controller and battery system monitor/setup
Table of Contents

Advertisement

Blue Sky Energy – IPN ProRemote
SET BAT AMP-HRS
220AH
SET CHG EFICENCY
94%
SET CHGEFCY MODE
AUTO ADJUST SEL►
SET SELF-DISCHG
12%/MONTH
17%/MONTH
+1980AH
SET MAXIMUM BAT
VOLTS 15.5V SEL►
17%/MONTH
+1980AH
SET AUX OUT MODE
BAT VOLTS
-9876543AH CLR►
SET AUX OUT OFF
<
11.5V
SET AUX OUT ON
>
12.6V
POST-DUSK LIGHTS
ON 2.5 HRS
PRE-DAWN LIGHTS
DISABLED
SET BACK-LIGHT
AUTO
-9876543AH CLR►
RESET CURRENT
SHUNT ZERO
-9876543AH CLR►
RESTORE DEFAULT
SETINGS
-9876543AH CLR►
SET BAT CHARGE
PARAMETERS
7
From Advanced Display menu
SEL►
SEL►
SEL►
SEL►
CLR►
SEL►
CLR►
SEL►
SEL►
SEL►
SEL►
SEL►
SEL►
Title:
SET►
From AutoCAD Drawing "f :\RVpower\ autocad\library\W AR-CAUT"
Creat or:
Aut oCAD
Preview:
This EPS picture was not saved
SET►
with a preview included in it.
Comment:
This EPS picture will print t o a
PostScript printer, but not t o
SEL►
ot her t ypes of printers.
To Battery Charge Parameters menu if selected.
FIGURE 3 - SETUP Menu
Total battery amp-hours at 25C, 20hr rate.
With charge efficiency set to 94%, battery is expected to retain 94 amp-
hours for each 100 amp-hours of charge. With charge efficiency mode set
to FIXED, charge efficiency value remains as set. If set to AUTO ADJUST it
automatically adjusts based on actual charge efficiency to continuously
improve remaining battery capacity accuracy.
Self discharge rate in percent per month at 25C.
Maximum charge voltage setpoint limit regardless of other settings or
temperature compensation.
Sets IPN Master charge controller "load control" mode to be based on
battery VOLTS or battery AMP-HOURS. Setting units (V or AH) in setting
screens change based on present mode setting.
--------------
Note: Be certain to set voltage settings even if using amp-hour control as
the charge controller will default to voltage control if battery amp-hours
are unavailable.
Enables, disables and sets ON time for lighting control mode. Lighting
control mode is disabled if BOTH Post-Dusk and Pre-Dawn timers are set
to DISABLED (<0.5 hrs). Lighting control mode is enabled if EITHER Post-
Dusk or Pre-Dawn timers are set to a time value. See charge controller
operators manual.
Sets display backlight to ON, OFF or AUTO. In AUTO, backlight remains ON
for one minute following last key press.
Corrects for "zero offset" in net battery current display.
CAUTION: Be certain shunt signal is a true zero before performing this
function or inaccurate battery current & amp-hour readings will result.
See Resetting Current Shunt Zero section of manual before proceeding!
Restores all factory default settings in the IPN ProRemote and charge
controllers, except for auxiliary output settings in slave controllers. Only
the Master's auxiliary output settings are available over the IPN network
and are restored.
FIGURE 4
--------------
Blue Sky Energy | USA |