Blue Sky Energy – IPN ProRemote

MENUS

There are four menus; Top, Advanced Display, Setup, and Battery Charge Parameters. Displays typically accessed by most users such as battery voltage,
net battery current and remaining battery capacity are present in the Top menu. More technical users may access additional menus where advanced
displays and setup capability reside. Refer to menu Figures 2, 3, 4 and 5.
BATTERY VOLT/AMP
12.6V
INPUT
+19.8A
BATTERY CAPACITY
███████
BATTERY AMP-HRS
FROM FULL
AUX BAT
12.0V
EQUALIZE NOW AT
AT 15.4V?
ENTER ADVANCED
DSPLY/SETUP SEL►
5
+25.0A
CHG OUT
+25.8A
70%
-150
LOAD CONTROL
AUX CHG
OUTPUT
-ON-
EQLZ 120min LEFT
AT 15.4V
SEL►
To Advanced Display/Setup
menus if selected.
TOP MENU
Shows battery voltage and "net" battery current. Net battery current is
the algebraic sum of all chargers and loads connected to the battery. A
positive value is charging, whereas a negative value is discharging. +30
amps of charge current and –5 amps of load current will display a net
current of +25.0amps.
Sum of input and output current for all charge controllers on the IPN
network.
Total battery amp-hours from full. Amp-hours from full are used to
compute remaining battery capacity which is shown as Percent
Remaining and as a Bar Graph. Dashes ( – – – ) are shown until the
battery is fully charged by the accompanying charge controller and the
100% full charge point is established.
Shows either IPN Master auxiliary battery voltage and charge ON/OFF
status, or load control status depending on function selected in the
charge controller.
-ON-
CLR►
WARNING: Not all batteries can be
safely equalized. Always follow battery
manufacturers recommendations
pertaining to equalization.
Selecting "Equalize Now" starts the
equalization cycle unless equalize is
disabled in the charge controller.
Equalize continues until equalize "time
at voltage" time accumulator counts
down to zero minutes left, or equalize
is manually canceled with "CLR►".
Note the voltage shown is the basic
equalize setpoint and does not include
the effects of temperature
compensation.