BLUE SKY IPN ProRemote Installation And Operation Manual page 7

Ipn network compatible charge controller and battery system monitor/setup
Table of Contents

Advertisement

LAST FULL CHARGE
10 DAYS AGO
LAST EQUALIZE
22 DAYS AGO
MAX BAT VOLTS
15.4V
MIN BAT VOLTS
11.9V
TOTAL CHG AMP-HR
+1980AH
LIFETIME BAT AH
-9876543AH CLR►
BAT TEMPERATURE
25C
+1980AH
VIEW CHARGE UNIT
STATUS
ENTER SETUP
MENUS
Controller address #0 – 7. NEXT scrolls through each
controller status screen. BACK returns to Advanced Display
menu. * Screen will be blank except for address if
controller not communicating on network.
Blue Sky Energy | USA |
www.blueskyenergyinc.com
From Top menu
CLR►
CLR►
CLR►
77F
CLR►
SEL►
Internal temperature *
SEL►
To Setup menus
if selected.
FIGURE 2
ADVANCED DISPLAY Menu
Days since last full charge or equalize. The equalize day counter resets
upon commencing equalize.
Day counter accuracy is +1 / -0 days as day counter transitions occur
following each 24 hour period from when battery power was applied.
Consider applying battery power late in the evening to improve counter
accuracy. Maximum range is 255 days which is also shown if days are
unknown.
Captures minimum and maximum battery voltage since last cleared.
Captures total output amp-hours of all charge controllers on the IPN
network since last cleared.
Serves as battery "odometer" capturing total discharge amp-hours since
last cleared. Value saved to non-volatile memory once per day.
Shows present battery temperature if optional sensor installed on charge
controller.
Selects status display of controllers on IPN network.
0 +25C OUT 12.3A
IN 17.5V
7 +29C OUT 14.5A
IN 18.5V
Installation and Operation Manual
12.0A
Output current *
15.0A
PV Input current *
PV Input voltage *