Clearances To Combustibles - Re-Verber-Ray MP-25-80N Insert Manual

Mp series modulating plus tube heater
Table of Contents

Advertisement

1.0
Safety • Safety Labels and Locations • Clearance to Combustibles
SERVICE ACCESS PANEL
IGNITER & FLAME SENSE COMPARTMENT
1. Turn off gas & electricity.
2. Remove cover by lifting top
cover upward and outward.
CAUTION: HOT SURFACE.
KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.
F/N: LLTB026
SERVICE ACCESS PANEL
IGNITER & FLAME SENSE COMPARTMENT
1. Disconnect gas & electricity.
2. Remove cover by lifting top
cover upward and outward.
CAUTION: HOT SURFACE.
KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.
SERVICE ACCESS PANEL
F/N: LLTB025R
Fan Compartment
F/N: LL01 - Clearance Safety Tag
(Affix adjacent to heater's thermostat)
Clearance to Combustibles
Clearance to combustibles is defined as the minimum distance that must exist between the tube surface,
or reflector, and any combustible items (see Figure 1.1). It also pertains to the distance that must be
maintained from moving objects around the tube heater.
SERVICE ACCESS PANEL
F/N
RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER
®
FOR OUTDOOR USE AND INDOOR (Non-Residential) INSTALLATION ONLY.
Class IIIA Permanent Label
MODEL NO.
INPUT BTU/H
FOR USE WITH
MP-40-150N
155,000 / 150,000 / 98,000
Natural Gas
MP
Volts AC:
Manifold Pressure:
Heater Type
120V - 60Hz
3.5 in.
W.C.P.
C1
AMPS - Starting:
Maximum Inlet Pressure:
Minimum Mounting Angle:
4.8
14 in.
W.C.P.
0
DEGREES
AMPS - Running:
Minimum Inlet Pressure:
Maximum Mounting Angle:
1.1
5.0 in.
W.C.P.
45
DEGREES
Combustion Chamber:
4" Black Coated Aluminized
For stainless steel upgrades: The combustion tube is 409 Series stainless steel.
DESIGN COMPLIES WITH:
ANSI Z83.20b-2004-GAS FIRED LOW INTENSITY INFRA-RED HTR.
DETROIT RADIANT PRODUCTS COMPANY
Serial No.: 1011XXXXXXXXXX 0001
21400 HOOVER ROAD - WARREN, MI
(586) 756-0950
-
www.drp-co.com
Controls Compartment
16" Burner Tube
WARNING
!
Placement of explosive objects, flammable objects, liquids and vapors close to
the heater may result in explosion, fire, property damage, serious injury or death.
Do not store or use explosive objects, liquids or vapor in the vicinity of the heater.
MP-40-150N
Production Code:
Version:
10.11
Data on this label is for the model shown on this label. If your heater has been converted,
this information is not accurate. Please contact the factory for assistance.
BURNER COMPONENTS:
Gas Valve:
Valve Assy - Nat
Circuit Board:
Mod Controller
Wire Harness:
Mod Wiring Harness
N.O. Switch:
None
N.O. VL Orifice:
None
N.C. Switch:
None
N.C. VL Orifice:
None
Diff Switch:
IS22010051F5166
Diff VL Orifice:
Grey (+ / -)
Igniter:
Norton
:
LLTB024L
Burner:
Mid
16" Tube:
4" Gen.
Ind. Lights:
Yellow - 24V
HEATER
Orifice Type:
TYPE:
Gas:
C1
Air:
Burner Control Box Component Label
(located inside the center compartment lid)
MODEL NO.
MP-40-150N
Volts AC:
120V - 60Hz
AMPS - Starting:
4.8
AMPS - Running:
1.1
Combustion Chamber:
4" BC Titanium
DESIGN COMPLIES WITH:
ANSI Z83.20b-2004-GAS FIRED LOW INTENSITY INFRA-RED HTR.
DETROIT RADIANT PRODUCTS COMPANY
21400 HOOVER ROAD - WARREN, MI
(586) 756-0950
-
Combustion Chamber
!
AVOID EQUIPMENT FAILURE
THIS 10 FT. TUBE IS THE
COMBUSTION CHAMBER.
The combustion chamber utilizes either 409
stainless, titanium alloy or aluminized steel -
depending on the model number of your heater.
Rotate the tube's welded seam to bottom.
Consult the manual(s) for further details.
(150,000 - 200,000 BTU/h models only)
4
MP
Serial #: 0112DETR21400 0001
Add-on:
None
MP-150
Stock:
N/A
(Specify TP-#'s)
3240
Diag. Light:
1428
3250
Term. Block:
None
N/A
3254
Transformer:
40 VA
826
N/A
Fan:
Fasco Lg.
3015
Alt. Fan:
50Hz - 120V
None
N/A
Alt. Fan Usage:
When Specified
Relay:
Picker x2
None
1264A
Filter:
None
N/A
24 Volt In:
3 T-plug
50
120 Volt In:
6' Blk. Cord
333
201B
Gas In:
7/8" FC
FC-36
3380
Extra VL Orifice:
None
328
Internal Use Only:
C1
C2
C3
Electric:
Special 1:
TP-204#
X
X
X
LLWT0XX
X
Tag:
Special 2:
TP-3014#
X-X"
X-X"
X-X"
None
X.X"
RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER
®
FOR OUTDOOR USE AND INDOOR (Non-Residential) INSTALLATION ONLY.
Class IIIA Permanent Label
INPUT BTU/H
FOR USE WITH
155,000 / 97,000
Natural Gas
Manifold Pressure:
Heater Type
4.1 in.
W.C.P.
C1
Maximum Inlet Pressure:
Version:
14.0 in.
W.C.P.
10/11
Minimum Inlet Pressure:
Minimum Mounting Angle:
5.0 in.
W.C.P.
0
Degrees
Maximum Mounting Angle:
For stainless steel upgrades: The combustion
45
Degrees
tube is 409 Series stainless steel.
Serial No.: 1011DETR021400 0001
www.drp-co.com
Radiant Tube(s)
INSTALLER
F/N: LLTB004
(orange)
Series
Rating
Plate

Hide quick links: