7.3 Viewing Measurement Data

Respectively, the last measurement value can be
displayed.
To view measurement data, please proceed as fol-
lows:
Briefly press the key "Clear/Recall" (13). The
last memory location number is displayed.
After this, the measurement data and the pre-
selected limit values are displayed for approx.
3 seconds.
If a number (e.g. 12) is displayed in lieu of a
measurement value, this indicates that a UUT
number has been stored at the last memory lo-
cation and no measurement has been stored
hereafter.
Attention, extended pressing (longer than 2s)
of the key "Clear/Recall" (13) causes the last
measurement value to be deleted.
7.4 Printing Measurement Data
After having saved the measurement result, it is
possible to print a report containing the measure-
ment results. For this, the UNITEST Protocol Print-
er (Cat. No. 1196) and the Interface Adapter (Cat.
No. 1157) are required (option).
As desired, the saved measurement data for the last
UUT or for all UUTs may be printed.
To print the measurement data, please proceed as
follows:
Perform the desired measurements and save
these measurements by pressing the key
"Store" (10), please refer to section 7.1 and 7.2.
Apply the TELARIS Interface Adapter (Cat. No.
1157) onto the TELARIS 0751.
Viewing Measurement Data/Printing Measurement Data
Connect the serial connection cable with the
protocol printer.
Switch on the printer and set the interface pa-
rameter on the protocol printer in compliance
with the TELARIS 0751 (9600 Baud, 8 data bit,
1 Stopbit, no parity).
To print out the saved measurement values of
the last UUT, briefly press the key "Print" (14).
"Prt" is displayed on the screen. The data is
transferred to the protocol printer. During the
printing process, the number of the memory lo-
cations remaining for printing is indicated as
countdown.
To print all saved measurement values, press
the key "Print" (14) slightly longer (approx. 2
seconds). "Prt" is displayed and the data is
transferred to the protocol printer. During the
printing process, the number of the memory lo-
cations remaining for printing is indicated as
countdown.
The printing of more than 10 data records can
be cancelled by pressing the key "Print" (14).
For this, press the key "Print" (14) after the
printout of the 10th data record. Leave the key
depressed until the printout is cancelled.
Imperatively observe the interface settings of
the protocol printer and accordingly set the in-
terface parameter of the TELARIS 0751 (9600
Baud, no parity, 8 data bit, 1 stop bit, please
refer to the technical data section). Please refer
to the instruction manual supplied with the pro-
tocol printer (Cat. No. 1196) for printer pa-
rameter setting.